NYC 9/11 Public Portal Document
Quantitation Report (Not Reviewed)
Data File C:\HPCHEM\l\DATA\02apr01\0401C10.D Vial 2
Acq On 1 Apr 2002 10:09 am Operator 201-wb
Sample cal 10 Inst GC/MS Ins
Mise Multiplr 1.00
MS Integration Params: RTEINT.P
Quant Time: Apr 1 10:47 2002 Quant Results File: HP031802.RES
Quant Method : C:\HPCHEM\1\METHODS\HP031802.M (RTE Integrator)
.Title : VOCs BY EPA METHOD 524
Last Update : Thu Mar 28 15:03:13 2002
Response via : Initial Calibration
DataAcq Meth : HP031802
Compound R.T. Qlon Response Cone Unit Qvalue
48) P & M-XYLENE 22.07 106 1242054 17.97 ug/L 91
49) 0-XYLENE 23.05 91 1386353 8.71. ug/L 95
50) STYRENE 23.10 104 860056 8.14 ug/L 96
51) 1,1,2,2-TETRACHLOROETHANE 24.13 83 228303 7.84 ug/L 92
53) BROMOFORM 23.97 173 168593 10.61 ug/L 98
54) ISOPROPYLBENZENE 23.77 105 1546401 9.74 ug/L 100
55) 1,2,3-TRICHLOROPROPANE 24.45 110 80710 9.48 ug/L 100
56) N-PROPYLBENZENE 24.64 91 1915414 9.29 ug/L 97
57) BROMOBENZENE 24.87 156 399034 9.56 ug/L 97
58) 1,3,5-TRIMETHYLBENZENE 24.96 105 1397398 9.93 ug/L 99
59) 2-CHLOROTOLUENE 25.13 91 1412066 9.95 ug/L 96
60) 4-CHLOROTOLUENE 25.20 91 1092933 8.95 ug/L 97
61) TERT-BUTYLBENZENE 25.74 119 1230789 9.58 ug/L 94
62) 1,2,4-TRIMETHYLBENZENE 25.84 105 1447496 9.83 ug/L 94
63) SEC-BUTYLBENZENE 26.20 105 1639184 9.29 ug/L 96
64) P-ISOPROPYLTOLUENE 26.47 119 1323701 9.61 ug/L 96
65) 1,3-DICHLOROBENZENE 26.83 146 726770 9.13 ug/L 98
66) 1,4-DICHLOROBENZENE 27.04 146 739801 8.99 ug/L 99
67) N-BUTYLBENZENE 27.36 91 1340293 9.57 ug/L 99
68) 1,2-DICHLOROBENZENE 27.90 146 616384 9.05 ug/L 98
69) 1,2-DIBROMO-3-CHLOROPROPAN 29.68 157 34449 8.20 ug/L 96
70) 1,2,4-TRICHLOROBENZENE 31.97 180 422016 9.81 ug/L 97
71) HEXACHLOROBUTADIENE 32.28 225 270692 12.17 ug/L 95
72) NAPHTHALENE 32.82 128 406493 7.70 ug/L 99
73) 1,2,3-TRICHLOROBENZENE 33.54 180 336672 10.01 ug/L 98
74) NITROBENZENE 29.90 77 173019 162.00 ug/L 92
(#) = qualifier out of range (m) = manual integration
0401C10.D HP031802.M Mon Apr 01 10:47:57 2002 Page 2
NYC-WTC_000081495
OCR can misread numbers and units. Confirm readings against the page image before using them.