WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: CCV STD2 60+5 PPB Sample Date/Time: Tuesday, May 14, 2002 13:48:25 Sample Type: Sample Sample Description: Number of Replicates: 3 Method File: c:\winnt\profiles\lrd1\elandata\Method\NEWQ200.8.mth Dataset File: c:\winnt\profiles\lrd1\elandata\Dataset\newyork city\CCV STD2 60+5 PPB.057 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Conc. Mean Cone. RSD Sample Unit Be 9 26239.749 1.611 0.049 59.27957 2.61 ug/L > Se-1 45 538816.890 2.053 538816.890 ug/L Cr 52 734120.425 9.773 1.348 63.07539 10.67 ug/L Cr 53 82426.525 1.382 0.152 59.74636 3.30 ug/L Mn 55 1152887.511 1.323 2.139 59.58792 3.19 ug/L Ni 60 170409.793 0.966 0.316 59.70988 2.98 ug/L Cu 63 368141.774 0.286 0.683 60.41584 2.31 ug/L Cu 65 175149.288 0.794 0.325 60.04453 1.33 ug/L Zn 66 118025.784 1.136 1.031 60.77878 1.67 ug/L Zn 67 20724.137 1.078 0.181 60.73956 0.70 ug/L Zn 68 88047.879 0.519 0.769 60.77931 0.56 ug/L Ge 72 113577.563 0.533 113577.563 ug/L As 75 144405.160 1.431 1.227 59.83521 2.04 ug/L Se 77 13742.443 2.895 0.114 60.15243 3.61 ug/L Se 82 15199.005 2.524 0.134 59.18070 2.89 ug/L Kr 83 2165.613 2.134 -339.091 ug/L Ag 107 767684.931 1.025 0.505 58.77932 1.74 ug/L > In 115 1519896.288 1.197 1519896.288 ug/L Sb 121 567219.648 0.465 0.373 60.38754 1.48 ug/L Sb 123 434409.092 0.597 0.286 60.82833 1.03 ug/L Ba 135 176264.837 0.434 0.067 52.30937 1.23 ug/L Ba 137 306825.074 0.770 0.117 51.77069 0.59 ug/L Tb 159 2619532.746 0.970 2619532.746 ug/L Hg 201 7415.431 0.148 0.003 4.52029 1.10 ug/L Hg 202 16819.380 0.920 0.006 4.49143 1.89 ug/L TI 205 2593832.684 0.560 0.990 65.82637 . 1.54 ug/L Pb 208 2668271.082 1.289 1.017 54.53628 0.40 ug/L
QC Calculated Values Analyte Mass QC Std % Recovery Int Std % Recovery Spike % Recovery Dilution % Diff Dup. Rel. % Diff Be 9 > Sc-1 45 76.460 Cr 52 Cr 53 Mn 55
Sample ID: CCV STD2 60+5 PPB Report Date/Time: Tuesday, May 14, 2002 13:50:28 Page 1
NYC-WTC_000053502
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000053094
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 8, 2002.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053337
Daily instrument calibration and performance verification log for ICPMS equipment conducted on April 25, 2002.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040925
Summary report of water sample analysis using Method 200.8 showing measured intensities and concentrations for various metals.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040700
Summary report of water sample analysis using Method 200.8 showing measured intensities and concentrations for various metals.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040648
Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040871
Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040755
Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040341
Summary report of water sample analysis using Method 200.8 showing measured intensities and concentrations for various metals.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040452
Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040598
Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000040287
Daily instrument performance verification log for ICPMS analysis including intensity and standard deviation data for multiple elements.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000078316
Laboratory report from Westchester County Dept of Labs and Research detailing Method 200.8 metal concentrations in water samples dated April 8, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000053094
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053094
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 8, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053337
Daily instrument calibration and performance verification log for ICPMS equipment conducted on April 25, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053094
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 8, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054375
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000053388
Administrative record from DEP Box 29 documenting ICPMS activities at the World Trade Center site in May 2002.
Filed in the same folder
NYC-WTC_000053094
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 8, 2002.
Similar indexed content
NYC-WTC_000053337
Daily instrument calibration and performance verification log for ICPMS equipment conducted on April 25, 2002.
Similar indexed content
NYC-WTC_000040925
Summary report of water sample analysis using Method 200.8 showing measured intensities and concentrations for various metals.
Similar indexed content
NYC-WTC_000040700
Summary report of water sample analysis using Method 200.8 showing measured intensities and concentrations for various metals.
Similar indexed content