ICPMS daily performance check report, May 3, 2002

Machine-extracted title · confidence 98%

Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.

NYC-WTC_000052963–000053092

Folder label: “ICPMS 5/3/02

Page image
Scanned page image, NYC-WTC_000053001
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Cr 53 97.913 Mn 55 86.711 Ni 60 104.007 Cu 63 98.475 Cu 65 98.487 Zn 66 101.591 Zn 67 94.681 Zn 68 103.972 Ge 72 89.999 As 75 107.419 Se 77 113.283 Se 82 111.871 Ag 107 93.118 Cd 111 103.780 Cd 114 100.324 > In 115 94.579 Sb 121 100.257 Sb 123 106.020 Ba 135 96.056' Ba 137 101.531 Ho 165 > Tb 159 93.944 Hg 201 100.179 Hg 202 100.223 TI 205 102.407 Pb 208 96.282 Calibration Analyte MassCurve Type Correlation Coefficient Be 9Linear Thru Zero 0.999570 Sc-1 45Linear Thru Zero Cr 52Linear Thru Zero 0.999516 Cr 53Linear Thru Zero 0.999999 Mn 55Linear Thru Zero 0.999735 Ni 60Linear Thru Zero 0.999662 Cu 63Linear Thru Zero 1.000000 Cu 65Linear Thru Zero 0.999636 Zn 66Linear Thru Zero 0.999967 Zn 67Linear Thru Zero 0.999861 Zn 68Linear Thru Zero 1.000000 > Ge 72Linear Thru Zero As 75Linear Thru Zero 0.999965 Se 77Linear Thru Zero 0.999622 Se 82Linear Thru Zero • 0.999911 Ag 107Linear Thru Zero 0.999575 Cd 111Linear Thru Zero 0.999957 Cd 114Linear Thru Zero 0.999484 > in 115Linear Thru Zero Sb 121Linear Thru Zero 0.999939 Sb 123Linear Thru Zero 0.999959 Ba 135Linear Thru Zero 0.999980 Ba 137Linear Thru Zero 0.999748 Ho 165Linear Thru Zero > Tb 159Linear Thru Zero

Sample ID: AE08755 Report Date/Time: Friday, May 03, 2002 12:02:51 Page 2

NYC-WTC_000053001

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000053001Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →