NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Laboratory analysis results for a Westchester County Department of Labs and Research sample processed on May 15, 2002.
NYC-WTC_000053630–000053704Folder label: “ICPMS 5/15/02 B”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WESTCHESTER COUNTY DEPT OF LABS AND RESEARCH Method 200.8 - Summary Report Sample ID: Blank Sample Date/Time: Wednesday, May 15,2002 14:12:37 Sample Type: Sample Sample Description: Number of Replicates: 3 Method File: c:\winnt\profiles\lrd1\elandata\Method\_NEWN.mth Dataset File: c:\winnt\profiles\lrd1\elandata\Dataset\newyork citBlank.101 Aliquot Volume (mL): Diluted To Volume (mL):
Concentration Results Analyte Mass Meas. Intens. Mean Meas. Intens. RSD Net Intens. Mean Cone. Mean Cone. RSD Sample Unit Be 9 9.333 6.186 ug/L Li 6 57888.397 2.808 ug/L > Sc-1 45 468174.916 1.490 ug/L Cr 52 6973.077 2.519 ug/L Cr 53 684.366 2.599 ug/L Mn 55 911.055 3.060 ug/L Co 59 121.335 3.895 ug/L Ni 60 61.668 27.915 ug/L Cu 63 405.346 6.785 ug/L Cu 65 201.338 5.757 ug/L Zn Zn 66 67 730.037 148.003 1.349 12.659 Revewed/ 0y ug/L ug/L Zn 68 622.694 7.038 ug/L > Ge 72 101305.395 1.295 ug/L As 75 5182.026 4.634 ug/L Se 77 714.957 2.728 ug/L Se 82 -12.506 947.038 ug/L As-1 75 137.669 3.276 ug/L Kr 83 1974.901 2.260 ug/L Ag 107 611.360 6.511 ug/L Cd 111 60.334 16.602 ug/L Cd 114 117.740 22.991 ug/L > In 115 1387006.510 1.204 ug/L Sb 121 69.668 10.384 ug/L Sb 123 63.729 11.884 ug/L Ba 135 76.668 8.386 ug/L Ba 137 118.669 5.611 ug/L Ho 165 2043410.070 0.362 ug/L > Tb 159 2012015.267 1.042 ug/L Hg 201 58.001 15.802 ug/L Hg 202 108.668 5.623 ug/L n 205 508.019 3.056 ug/L Pb 208 2350.809 1.188 ug/L
QC Calculated Values
Sample ID: Blank Report Date/Time: Wednesday, May 15, 2002 14:14:33 Page 1
NYC-WTC_000053630
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
1 shared topics · Same agency, volume and box · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053939
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 21, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054670
Document page from the Department of Environmental Protection ICPMS series dated May 31, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054375
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054747
Westchester County Department of Labs and Research report detailing elemental analysis results for sample AE12151 using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054886
Westchester County Department of Labs and Research report detailing elemental analysis results for sample ID [name] using ICPMS Method 200.8.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053212
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 9, 2002.
1 shared topics · Same agency, volume and box · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052963
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 3, 2002.
1 shared topics · Same agency, volume and box · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000077278
Summary of water sample results for metals analysis using Method 200.8 conducted on March 19, 2002.
1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054886
Westchester County Department of Labs and Research report detailing elemental analysis results for sample ID [name] using ICPMS Method 200.8.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054670
Document page from the Department of Environmental Protection ICPMS series dated May 31, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053212
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 9, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000054375
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 24, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000053389
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 14, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000053629
Administrative record from DEP Box 29 documenting ICPMS activities at the World Trade Center site in May 2002.
Filed in the same folder
NYC-WTC_000053505
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 15, 2002.
Similar indexed content
NYC-WTC_000053706
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 16, 2002.
Similar indexed content
NYC-WTC_000054548
Document page from the Department of Environmental Protection ICPMS series dated May 30, 2002.
Similar indexed content
NYC-WTC_000054157
Daily instrument calibration and performance verification log for ICPMS equipment conducted on May 22, 2002.
Similar indexed content