GCMS analysis results for sample AE00613, Feb 2002

Machine-extracted title · confidence 100%

Laboratory report showing GCMS analysis results for sample AE00613 conducted on February 1, 2002.

NYC-WTC_000051586–000051604

Folder label: “GCMS X 1/9/02 A 1/29/02

Page image
Scanned page image, NYC-WTC_000051588
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

yuaiu 4 La L LOI Keport (Not Reviewed)

Data File : C:\MSDCHEM\1\5973N\02JAN29\00613.D Vial: 2 • Acg On : 29 Jan 2002 3:25 pm Operator: Sample : 508 scan Inst : Instrumen Mise : January 29, 2002 Multiplr: 1.00 MS Integration Params: SPLIT.P Quant Time: Jan 30 08:25:55 2002 Quant Results File: SCAN508.RES Quant Method : C:\MSDCHEM\l..-\SCAN508.M (RTE Integrator) Title : 508 scan method Last Update : Fri Jan 11 13:20:07 2002 Response via : Initial Calibration DataAcq Meth : SCANS08

Internal Standards R.T. Qlon Response Conc.Units Dev(Min) 1) 1,4-Dichlorobenzene-d4 9.72 152 1779352 20.00 ug/L 0.00 10) Naphthalene-d8 13.19 136 7477289 20.00 ug/L -0.02 17) Acenaphthene-dlO 18.34 164 3753929' 20.00 ug/L -0.01 29) Phenanthrene-dlO 22.65 188 6363722 20.00 ug/L -0.02 38) Chrysene-dl2 30’, 50 240 6102984 20.00 ug/L -0.01 44) Perylene-dl2 34.42 264 4622208 20.00 ug/L 0.00 System Monitoring Compounds 37) 2,4-DDD 27.73 235 460627 4.58 ug/L 0.00 Spiked Amount 5.000 Recovery = 91.60% Target Compounds Qvalue 20) Dimethylphthalate 18.34 163 605882 2.44 ug/L # 57 21) 2,6-Dinitrotoluene 18.34 165 474843 9.82 ug/L # 17 42) Bis(2-ethylhexyl)phthalate 31.11 149 65083 0.76 ug/L 98

(#) = qualifier out of range (m) = manual integration 00613 .D SCAN508 .M Wed Jan 30 08:25:56 2002 Page 1

NYC-WTC_000051588

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000051588Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →