NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 28/GCMS X 1/4/02 A 2/4/02
Document / 18 pages

GCMS blank analysis results for sample AE00110, Feb 2002

Machine-extracted title · confidence 100%

Laboratory report showing non-detect results for volatile organic compounds in a GCMS blank analyzed on February 4-7, 2002.

NYC-WTC_000050627–000050644

Folder label: “GCMS X 1/4/02 A 2/4/02

Page image
Scanned page image, NYC-WTC_000050628
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document •*t

Data File : C:\MSDCHEM\l\5973N\02FEB04\0204BB.D Vial: 1 Acq On : 4 Feb 2002 10:58 am Operator: Sample : lab blank l/4b Inst : Instrumen Mise : February 4, 2002 Multiplr: 1.00 MS Integration Params: SPLIT.P Quant Time: Feb 05 08:28:37 2002 Quant Results File: SCAN508.RES Quant Method : C:\MSDCHEM\1...\SCAN508 .M (RTE Integrator) Title : 508 scan method Last Update : Fri Jan 11 13:20:07 2002 Response via : Initial Calibration DataAcq Meth : SCAN508

Internal Standards R.T. Qlon Response Cone Units Dev(Min) 1) l,4-Dichlorobenzene-d4 9.71 152 1478126 20.00 ug/L -0.01 10) Naphthalene-d8 13.19 136 6259613 20.00 ug/L -0.02 17) Acenaphthene-diO 18.34 164 3211325. 20.00 ug/L -0.01 29) Phenanthrene-diO 22.65 188 5329249 20.00 ug/L -0.02 38) Chrysene-dl2 30.50 240 4614583 20.00 ug/L -0.01 44) Perylene-dl2 34.42 264 3248108 20.00 ug/L 0.00 System Monitoring Compounds 37) 2,4-DDD 27.73 235 249810 2.97 ug/L 0.00 Spiked Amount 5.000 Recovery = 59.40% Target Compounds Qvalue 3) bis(2-Chloroethyl)ether 9.05 93 7984 Below Cal + 9 21) 2,6-Dinitrotoluene 18.34 165 400289 9.68 ug/L # 17 42) Bis(2-ethylhexyl)phthalate 31.11 149 17504 0.62 ug/L 95

(#) = qualifier out of range (m) = manual integration 0204BB.D SCAN508.M Tue Feb 05 08:28:38 2002 Page 1

NYC-WTC_000050628

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000050628Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →