NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 12/GCMS X 2/12/02 A 3/01/02
Document / 20 pages

GCMS analysis results for sample AE03185, March 2002

Machine-extracted title · confidence 95%

Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE03185 conducted on March 15, 2002.

NYC-WTC_000006065–000006084

Folder label: “GCMS X 2/12/02 A 3/01/02

Page image
Scanned page image, NYC-WTC_000006067
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Data File : C:\MSDCHEM\l\5973N\02MAR01\03185.D Vial: 5 . Acq On : 1 Mar 2002 1:38 pm Operator: Sample : 508 scan Inst : Instrumen Mise : March 1, 2002 Multiplr: 1.00 MS Integration Params: SPLIT.P Quant Time: Mar 04 10:50:46 2002 Quant Results File: HP022102.RES

Quant Method : C:\MSDCHEM\1...\HP022102 .M (RTE Integrator) Title : 508 scan method Last Update : Mon Feb 25 10:47:59 2002 Response via : Initial Calibration DataAcq Meth : HP020702

Internal Standards R.T. Qlon Response Cone Units Dev(Min)

1) l,4-Dichlorobenzene-d4 9.71 152 1379108 20.00 ug/L 0.00 10) Naphthalene-d8 13.20 136 5947792 20.00 ug/L 0.00 17) Acenaphthene-diO 18.33 164 3050413. 20.00 ug/L 0.00 29) Phenanthrene-dlO 22.63 188 5108476 20.00 ug/L -0.01 38) Chrysene-dl 2 30.49 240 4041085 20.00 ug/L -0.03 44) Perylene-dl2 34.41 264 2626120 20.00 ug/L -0.04

System Monitoring Compounds 37) 2,4-DDD 27.72 235 385216 5.66 ug/L 0.00 Spiked Amount 5.000 Recovery = 113.20%

Target Compounds Qvalue 20) Dimethylphthalate 18.33 163 493212 2.67 ug/L # 58 21) 2,6-Dinitrotoluene 18.33 165 388260 9.09 ug/L # 27

(#) = qualifier out of range (m) = manual integration 03185.D HP022102.M Mon Mar 04 10:50:47 2002 Page 1

NYC-WTC_000006067

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000006067Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →