GCMS analysis results for sample AE03245, March 2002

Machine-extracted title · confidence 95%

Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AE03245 conducted on March 15, 2002.

NYC-WTC_000006085–000006104

Folder label: “GCMS X 2/12/02 A 3/01/02

Page image
Scanned page image, NYC-WTC_000006087
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Data File : C:\MSDCHEM\1\5973N\02MAR01\03245.D Vial: 6 ♦ Acq On : 1 Mar 2002 2:28 pm Operator: Sample : 508 scan Inst : Instrumen Mise : March 1, 2002 Multiplr: 1.00 MS Integration Params: SPLIT.P Quant Time: Mar 04 10:50:48 2002 Quant Results File: HP022102.RES

Quant Method : C:\MSDCHEM\l..-\HP022102.M (RTE Integrator) Title : 508 scan method Last Update : Mon Feb 25 10:47:59 2002 Response via : Initial Calibration DataAcq Meth : HP020702

Internal Standards R.T. Qlon Response Cone Units Dev(Min)

1) 1,4-Dichlorobenzene-d4 9.71 152 1587119 20.00 ug/L 0.00 10) Naphthalene-d8 13.20 136 6878638 20.00 ug/L 0.00 17) Acenaphthene-diO 18.33 164 3418501. 20.00 ug/L 0.00 29) Phenanthrene-diO 22.63 188 5582169 20.00 ug/L -0.01 38) Chrysene-dl2 30.49 240 4417674 20.00 ug/L -0.03 44) Perylene-dl2 34.41 264 2895941 20.00 ug/L -0.04

System Monitoring Compounds 37) 2,4-DDD 27.72 235 429121 5.77 ug/L 0.00 Spiked Amount 5.000 Recovery = 115.40%

Target Compounds Qvalue 20) Dimethylphthalate 18.34 163 548244 2.64 ug/L # 57 21) 2,6-Dinitrotoluene 18.33 165 431368 9.01 ug/L # 27

(#) = qualifier out of range (m) = manual integration 03245.D HP022102.M Mon Mar 04 10:50:49 2002 Page 1

NYC-WTC_000006087

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000006087Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →