Quantitation Report (QT Reviewed)

Data File : C:\MSDCHEM\l\DATA\020419\08429.D Vial: 16 Acq On : 19 Apr 2002 10:54 pm Operator: Nefliu Sample : sample Inst : Instrumen Mise : Multiplr: 1.00 MS Integration Params: EVENTS.E Quant Time: Apr 26 14:51:19 2002 Quant Results File: SCAN020418.RE Quant Method : C:\MSDCHEM\1\METHODS\SCAN020418.M (Chemstation Integrator) Title : Method 508 GC/MS Scan Last Update : Mon Apr 22 08:00:39 2002 Response via : Initial Calibration DataAcq Meth : 508SCAN1

Internal Standards R.T. Qlon Response Cone Units Dev(Min) 1) 1,4-Dichlorobenzene-d4 11.38 152 10815323 40.00 ug/1 -0.05 10) Naphthalene-d8 ' 16.54 136 41607140 40.00 ug/1 -0.07 17) Acenaphthene-dl0 24.46 164 22893968 40.00 ug/1 -0.06 30) Phenanthrehe-dlO 31.72 188 34289348 40.00 ug/1 -0.06 38) Chrysene-dl2 39.94 240 26336914 40.00 ug/1 -0.07 44) Perylene-dl2 43.16 264 18921223 40.00 ug/1 -0.04 System Monitoring Compounds 27) TCMX 27.54 207 823333 5.79 ug/1 -0.07 Spiked Amount 10.000 Recovery = 57.90% Target Compounds .o 72. Qvalue 35) Di-n-butylphthalate 34.81 149 101442 0.08 ug/1 97 36) Fluoranthene 36.05 202 127792 0.13 ug/1 80 39) Pyrene 36.66 202 86325 0.08 ug/1 81

(#) = qualifier out of range (m) = manual integration (+) = signals summed 08429.D SCAN020418.M Fri Apr 26 15:04:00 2002 Page 1

NYC-WTC_000048209

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000048209Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →