GCMS reanalysis note for sample AE08264, May 6 2002

Machine-extracted title · confidence 100%

Laboratory comment noting low recovery in initial GCMS scan of sample AE08264, resulting in re-extraction.

NYC-WTC_000044338–000044348

Folder label: “GCMS X 4/23/02 A 4/26/02

Page image
Scanned page image, NYC-WTC_000044341
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (QT Reviewed)

Data File C:\HPCHEM\l\DATA\MAY0102\8264.D Vial: 3 Acq On 1 May 2002 9:55 am Operator: Sample gc/ms scan 4/23 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 1 10:52 2002 Quant Results File: GCMS0501.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed May 01 10:40:31 2002 Response via : Initial Calibration DataAcq Meth : GCMS0501

Compound R.T. Qlon Response Cone Unit Qvalue

35) Anthracene 25.59 178 307 N.D. 36) Di-n-butylphthalate 27.55 149 11456 0.30 ug/1 # 98 37) Fluoranthene 0.00 202 0 N.D. 39) Pyrene 0.00 202 0 N.D. 40) Butylbenzylphthalate 32.08 149 496 N.D. 41) Benzo(a)anthracene 33.64 228 2195 N.D. 42) Bis(2-ethylhexyl)phthalate 33.86 149 6355 0.38 ug/1 99 43) Chrysene 33.72 228 523 N.D. 45) Di-n-Octylphthalate 35.59 149 458 N.D. 46) Benzo(b)fluoranthene 36.70 252 278 N.D. 47) Benzo(k)fluoranthene 36.77 252 471 N.D. 48) Benzo(a)pyrene 37.69 252 319 N.D. 49) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 50) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration 8264.D GCMS0501.M Wed May 01 11:40:45 2002 Page 2

NYC-WTC_000044341

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000044341Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →