NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 23/GCMS X 2/19/02 A 3/8/02
Document / 20 pages

GCMS blank results for sample AE03509, March 28, 2002

Machine-extracted title · confidence 90%

Laboratory report documenting GCMS analysis of a method blank for sample AE03509 to verify analytical system cleanliness.

NYC-WTC_000037660–000037679

Folder label: “GCMS X 2/19/02 A 3/8/02

Page image
Scanned page image, NYC-WTC_000037662
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Quantitation Report (Not Reviewed) Data File : C:\MSDCHEM\l\5973N\02MAR08\03509 .D Vial: 5 Acq On : 8 Mar 2002 1:57 pm Operator: Sample : 508 scan Inst : Instrumen Mise : March 8, 2002 Multiplr: 1.00 MS Integration Params: SPLIT.P Quant Time: Mar 15 10:05:09 2002 Quant Results File: HP022102.RES Quant Method : C:\MSDCHEM\1...\HP022102 .M (RTE Integrator) Title : 508 scan method Last Update : Mon Feb 25 10:47:59 2002 Response via : Initial Calibration DataAcq Meth : HP022102

Internal Standards R.T. Qlon Response Cone Units Dev(Min) 1) 1,4-Dichlorobenzene-d4 9.71 152 1787593 20.00 ug/L 0.00 10) Naphthalene-d8 13.20 136 7733348 20,00 ug/L 0.00 17) Acenaphthene-diO 18.33 164 3843485 20.00 ug/L 0.00 2 9) Phenanthrene-dl0 22.63 188 6391131 20.00 ug/L -0.01 38) Chrysene-dl2 30.49 240 4955780 20.00 ug/L -0.03 44) Perylene-dl2 34.41 264 3231543 20.00 ug/L -0.04 System Monitoring Compounds 37) 2,4-DDD 27.72 235 383167 4.50 ug/L 0.00 Spiked Amount 5.000 Recovery = 90.00% Target Compounds Qvalue 20) Dimethylphthalate 18.33 163 614862 2.64 ug/L # 58 21) 2,6-Dinitrotoluene 18.33 165 487734 9.06 ug/L # 27

(#) = qualifier out of range (m) = manual integration 03509.D HP022102.M Fri Mar 15 10:05:10 2002 Page 1

NYC-WTC_000037662

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000037662Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →