NYC-WTC_000036044
Technical form recording method parameters, drip rates, and analytical data for GCMS testing procedures.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Blank sample analysis report for GCMS testing showing non-detect levels for target analytes.
NYC-WTC_000036350–000036359Folder label: “GCMS X 12/5/01 A 12/12/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
User: Vinci, David L Westchester Dept, of Labs & Research Date: 01/04/2002 Time: 1 2:1 2:57
Sample: AD29289 Analysis: $B1GCMS Blank for GCMS Scan Units: ug Started: 1/4/02 12:12 Ended: 1/4/02 12:12 Analyst: DLV Result source: manual entry Page: 1
Component Name Viol Result Qualifier ’ _—1 — n-Nitrosodimethylamine <: MDL 2.0 2 bis(2 Chioroethyl)ether < MDL 2.0
4 1,3-Dichlorobenzene 1,4-Dichlorobenzene < MDL < MDL 2.0 2.0 s 1 ,2-Dichlorobenzene < MDL 2.0 6 2,2’ -oxybis(1 -Chloropropane) < MDL 2.0 2 n-Nitrosodi-n- propylamine Hexachloroethane < MDL < MDL ... 2.0 2.0 2.0 . - 5 " Nitrobenzene < MDL - 10 isophorone < MDL _........... 2.0 11 bis(2-Chloroethoxy (methane < MDL 2.0 ’
3 1 ,2,4-Trichlorobenzene Naphthalene < MDL <MDL _ 2.0_ 2.0... 1a Hexachlorobutadiene < MDL 2.0 18 Hexachlorocyclopentadiene
........ 2 -Chloronaphthalene < MDL <MDL ........2 2.0 2.0
Dimethylphthalate <MDL 2.0 18 2,6-Dinitrotoluene <MDL 2.0.. 19 Acenaphthylene <MDL <MDL 2.0 brpint 20 Acenaphthene 2.0_ Oi. 2,4-Dinitrotoluene ......... ...... -. - < MDL ... 2.0 • 22 Diethylphthalate < MDL ....... 2.0 _ 23 4-Chlorophenylphenylether < MDL ..... 2.0 Fluorene <MDL 2.0_ ' 28 Azobenzene/1 2 Diphenylhydra < MDL 2.0 . 2.0 n-Nitrosodiphenylamine <MDL 4 Bromophenylphenylether < MDL 2.0 28 29 Hexachlorobenzene < MDL .............. 2.0 Phenanthrene < MDL 2.0 30 Anthracene < MDL
<MDL 2.0 Di-n-butylphthalate 2.0 .2 Fluoranthene < MDL ...... 2.0.. 33 Pyrene < MDL 2.0_ 34 Butylbenzylphthalate < MDL _...... 2.0_ 35 Benzo(a)anthracene < MDL .... 2.0 36 bis(2-Ethylhexyl|phthalate < MDL _.......... _ 2.0 37 Chrysene < MDL 2.0 38Di n-octylphthalate < MDL 2.0 39 Benzo(b)fluoranthene < MDL 2.0 40 Benzo(k)fluoranthene < MDL ..... 2.0 41" Benzo(a)pyrene < MDL 2.0 “42Ci Indeno(1 ,2,3-cd)pyrene < MDL 2.0_ 43 Dibenz(a,h)anthracene < MDL 2.0.. 44 Benzo(g,h,i)perylene < MDL ..... 2.0....
NYC-WTC_000036350
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000036044
Technical form recording method parameters, drip rates, and analytical data for GCMS testing procedures.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036210
Reference analysis results for target analytes used to verify GCMS instrument performance in December 2001.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035890
Laboratory data sheet recording GCMS analysis of a blank sample for nitrosamines and chlorinated compounds.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035776
Laboratory data sheet recording GCMS analysis of a blank sample for nitrosamines and chlorinated compounds.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000037219
Gas chromatography-mass spectrometry blank report for sample AD29932 analyzing nitrosamines and chlorinated compounds on December 18, 2001.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036079
Laboratory report showing GCMS scan results for sample AD29135 including detection of unknown compounds and surrogates.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035931
Laboratory report noting detection of Decanedioic acid bis(2-Ethylhexyl) ester in sample AD29027 on December 18, 2001.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035831
Lab notes for sample AD29141 indicate detection of bis(2-Ethylhexyl)phthalate and one LCS compound outside acceptance range.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036243
Laboratory analysis report for sample AD29235 conducted on December 28, 2001, including surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036391
Laboratory report documenting GCMS analysis of sample AD29298 conducted on January 4, 2002, showing unknown compounds and surrogates.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036311
Laboratory analysis report for sample AD29285 conducted on December 28, 2001, including surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036325
Laboratory GCMS analysis report for sample AD29229 conducted on December 28, 2001, including surrogate recovery data.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000036210
Reference analysis results for target analytes used to verify GCMS instrument performance in December 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035571
GCMS method blank analysis for sample AD28903 dated December 7, 2001, showing non-detect levels.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035788
Calibration data sheet verifying instrument response for nitrosamines and benzene derivatives.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000005154
Reference analysis report detailing quantitative results for multiple volatile organic compound standards analyzed on February 11, 2002.
Similarity score 0.944 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000033886
Technical data sheet recording instrument parameters and calibration details for GCMS Method 508 analysis conducted in November 2001.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000086570
Laboratory report for gas chromatography-mass spectrometry analysis of sample AD22485 conducted on September 24, 2001.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000036337
Department of Environmental Protection record logging GCMS X samples from November to December 2001.
Filed in the same folder
NYC-WTC_000036338
Laboratory report showing GCMS analysis results for sample AD29289 with surrogate and unknown compound data.
Filed in the same folder
NYC-WTC_000036341
Calibration log for GCMS analysis of sample AD29289 listing target analytes and detection limits.
Filed in the same folder
NYC-WTC_000036345
Reference standard analysis report for GCMS testing showing concentrations of target analytes and detection limits.
Filed in the same folder
NYC-WTC_000036360
Laboratory GCMS analysis report for sample AD29289 conducted on January 4, 2002, showing unknown compounds and surrogates.
Filed in the same folder