NYC-WTC_000035618
Lab report noting bis(2-Ethylhexyl)phthalate detection and recovery issues in a water sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Lab report noting bis(2-Ethylhexyl)phthalate detection, recovery issues, and low pH.
NYC-WTC_000035640–000035650Folder label: “GCMS X 11/29/01 A 12/7/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed) Data File C:\HPCHEM\l\DATA\DEC0701\28964.D Vial: 10 Acq On 7 Dec 2001 11:43 pm Operator: 209 GALOS Sample 11/29 gc/ms scan Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: RTEINT.P Quant Time: Dec 12 14:48 2001 Quant Results File: GCMS1126.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed Nov 28 15:06:24 2001 Response via : Initial Calibration DataAcq Meth : GCMS1126
Compound R.T. Qlon Response Cone Unit Qvalue 30) N-Nitrosodiphenylamine 0.00 168 0 N.D. 31) 4-Bromophenyl-phenylether 0.00 248 0 N.D. 3 2) Hexachlorobenzene 0.00 284 0 N.D. 33) Phenanthrene 25.03 178 152 N.D. 34) Anthracene 25.03 178 152 N.D. 35) Di-n-butylphthalate 26.99 149 26335 N.D. 3 6) Fluoranthene 0.00 202 0 N.D. 39) Pyrene 0.00 202 0 N.D. 40) Butylbenzylphthalate 31.50 149 986 N.D. 41) Benzo(a)anthracene 33.01 228 3746 N.D. 42) Bis(2-ethylhexyl)phthalate 33.29 149 39418 0.43 ug/1 96 43) Chrysene 33.01 228 3746 N.D. 45) Di-n-Octylphthalate 35.02 149 638 N.D. 46) Benzo(b)fluoranthene 36.06 252 174 N.D. 47) Benzo(k)fluoranthene 36.06 252 174 N.D. 48) Benzo(a)pyrene 37.10 252 4208 N.D. 49) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 50) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo (g,h, i)perylene 0.00 276 0 N.D.
(#) = qualifier out of range (m) = manual integration 28964.D GCMS1126.M Thu Dec 13 14:56:35 2001 Page 2
NYC-WTC_000035643
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035618
Lab report noting bis(2-Ethylhexyl)phthalate detection and recovery issues in a water sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035651
Lab report noting bis(2-Ethylhexyl)phthalate detection and recovery issues in a water sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036103
Laboratory report noting GCMS scan results for sample AD29189 with di-n-butylphthalate detected and low pH.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035629
Lab report noting no unusual compounds but recovery issues in a water sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035808
Laboratory analysis notes for sample AD29023 indicating no unusual compounds detected in GCMS scan; one of forty-three compounds in quality control standard outside acceptance rang
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036425
Laboratory report documenting GCMS analysis of sample AD29457 conducted on January 4, 2002, showing unknown compounds and surrogates.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035865
Lab notes for sample AD29134 indicate detection of di-n-butylphthalate and one LCS compound outside acceptance range.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036151
Laboratory report noting GCMS scan results for sample AD29231 with phthalates detected and low recovery requiring re-analysis.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035831
Lab notes for sample AD29141 indicate detection of bis(2-Ethylhexyl)phthalate and one LCS compound outside acceptance range.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034908
Repeat gas chromatography-mass spectrometry analysis of sample AD28596 after re-extraction, confirming bis(2-Ethylhexyl)phthalate at 0.36 ug/L with improved standard recovery of 89
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035853
Lab notes for sample AD29139 indicate detection of di-n-butylphthalate and one LCS compound outside acceptance range.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000036220
Blank sample results showing non-detect levels for target compounds during December 2001 laboratory testing.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035580
GCMS scan results for sample AD28903 dated December 15, 2001, detecting bis(2-Ethylhexyl)phthalate.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035765
Lab notes for sample AD28860 indicate no unusual compounds detected but recovery was below acceptance range.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035651
Lab report noting bis(2-Ethylhexyl)phthalate detection and recovery issues in a water sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035618
Lab report noting bis(2-Ethylhexyl)phthalate detection and recovery issues in a water sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035629
Lab report noting no unusual compounds but recovery issues in a water sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035755
Lab report noting bis(2-Ethylhexyl) Sebacate detection and potential laboratory contamination in a water sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000035561
Department of Environmental Protection record logging GCMS X samples from November to December 2001.
Filed in the same folder
NYC-WTC_000035562
Fragmented document header containing metadata for gas chromatography-mass spectrometry analysis.
Filed in the same folder
NYC-WTC_000035563
GCMS analysis results for sample AD28903 dated December 15, 2001, showing non-detect levels for various compounds.
Filed in the same folder
NYC-WTC_000035571
GCMS method blank analysis for sample AD28903 dated December 7, 2001, showing non-detect levels.
Filed in the same folder
NYC-WTC_000035575
GCMS reference standard analysis for sample AD28903 dated December 7, 2001, showing measured concentrations.
Filed in the same folder