NYC-WTC_000035692
Laboratory notes stating the GCMS scan of sample AD28902 revealed no unusual compounds.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
NYC-WTC_000035306–000035313Folder label: “GCMS X 11/26/01 A 12/6/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Area Percent Report
Data File C:\HPCHEM\l\DATA\DEC0501\28757.D Vial: 16 Acq On 6 Dec 2001 3:15 am Operator: 209 GALOS Sample 11/26 gc/ms scan Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: LSCINT.P
Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Smoothing : OFF Filtering: 5 Sampling : 1 Min Area: 1 % of largest Peak Start Thrs: 0.2 Max Peaks: 100 Stop Thrs : 0 Peak Location: TOP
If leading or trailing edge < 100 prefer < Baseline drop else tangent > Peak separation: 5
Signal : TIC
peak R.T. first max last PK peak peak peak % of # min scan scan scan TY height area % max. total
1 11.709 721 726 744 rBV 1861583 4830643 73.60% 15.218% 2 15.316 1113 1119 1137 rBV 2982281 6312002 96.17% 19.885% 3 20.586 1687 1693 1708 rBV 3011745 6563614 100.00% 20.678% 4 25.011 2168 2175 2187 rBV2 2681861 6033197 91.92% 19.007% 5 25.158 2187 2191 2202 rVB 23895 76373 1.16% 0.241%
6 30.078 2722 2727 2740 rVB 290032 598577 9.12% 1.886% 7 33.034 3042 3049 3069 rBV2 1802803 4219575 64.29% 13.293% 8 37.129 3488 3495 3516 rBV2 1094919 3108549 47.36% 9.793%
Sum of corrected areas: 31742530
28757.D GCMS1126.M Fri Dec 07 17:01:47 2001
NYC-WTC_000035311
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035692
Laboratory notes stating the GCMS scan of sample AD28902 revealed no unusual compounds.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035298
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035266
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035290
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035249
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035274
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035497
GCMS scan results for sample AD28858 dated December 16, 2001, showing no unusual compounds found.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035314
Laboratory report noting detection of bis(2-Ethylhexyl)phthalate in a WTC environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035330
Laboratory report noting detection of Di-n-butylphthalate in a WTC environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035322
Laboratory report noting detection of Di-n-butylphthalate in a WTC environmental sample.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035444
GCMS scan results for sample AD28800 dated December 16, 2001, showing no unusual compounds found.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035765
Lab notes for sample AD28860 indicate no unusual compounds detected but recovery was below acceptance range.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035330
Laboratory report noting detection of Di-n-butylphthalate in a WTC environmental sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035249
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035266
Laboratory report confirming no unusual compounds were detected in the analyzed environmental sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035257
Laboratory report noting recovery rates fell outside acceptance ranges for a WTC environmental sample.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035322
Laboratory report noting detection of Di-n-butylphthalate in a WTC environmental sample.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035737
Laboratory notes stating the GCMS scan of sample AD28862 revealed no unusual compounds.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000035229
Fragmented document page containing unreadable text and a sample ID from the DEP Box 22 archive.
Filed in the same folder
NYC-WTC_000035230
Partial document containing fragmented numerical data and method references for chemical analysis.
Filed in the same folder
NYC-WTC_000035233
Laboratory report showing non-detect levels for various volatile organic compounds in a WTC blank sample.
Filed in the same folder
NYC-WTC_000035240
Calibration record verifying instrument response factors for specific chemical compounds prior to analysis.
Filed in the same folder
NYC-WTC_000035244
Reference sheet listing expected values and detection limits for volatile organic compounds in WTC samples.
Filed in the same folder