NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
NYC-WTC_000035195–000035228Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\1\DATA\NOV2 601\28682.D Vial: 10 Acq On : 28 Nov 2001 2:05 am Operator: 209 GALOS Sample : 11/24 scan Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: RTEINT.P Quant Time: Dec 10 12:09 2001 Quant Results File: GCMS1126.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed Nov 28 15:06:24 2001 Response via : Initial Calibration DataAcq Meth : NP103001
Compound R.T. Qlon Response Cone Unit Qvalue
29) 2,4,5-Trichlorophenol 0.00 196 0 N.D. 30) 2-Chloronaphthalene 0.00 162 0 N.D. 31) Dimethylphthalate 0.00 163 0 N.D. 32) 2,6-Dinitrotoluene 0.00 165 0 N.D. d 33) Acenaphthylene 0.00 152 0 N.D. 34) Acenaphthene 0.00 153 0 N.D. 35) 2,4-Dinitrophenol 0.00 184 0 N.D. 36) 4-Nitrophenol 0.00 65 0 N.D. 37) 2,4-Dinitrotoluene 20.97 165 290 N.D. 38) Diethylphthalate 22.10 149 407 N.D. 39) 4-Chlorophenyl-phenylether 0.00 204 0 N.D. 4 0) Fluorene 0.00 166 0 N.D. 41) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D. 43) 4,6-Dinitro-2-methylphenol 0.00 198 0 N.D. 44) N-Nitrosodiphenylamine 0.00 168 0 N.D. 45) 4-Bromophenyl-phenylether 0.00 248 0 N.D. 46) Hexachlorobenzene 0.00 284 0 N.D. 47) Pentachlorophenol 0.00 266 0 N.D. 4 8) Phenanthrene 25.00 178 755 N.D. 49) Anthracene 25.00 178 755 N.D. 50) Di-n-butylphthalate 27.00 149 9042 N.D. 51) Fluoranthene 0.00 202 0 N.D. 54) Pyrene 0.00 202 0 N.D. 55) Butylbenzylphthalate 0.00 149 0 N.D. 5 6) Benzo(a)anthracene 33.02 228 2095 N.D. 57) Bis(2-ethylhexyl)phthalate 33.30 149 3575 N.D. 58) Chrysene 33.10 228 290 N.D. 60) Di-n-Octylphthalate 0.00 149 0 N.D. 61) Benzo(b)fluoranthene 36.08 252 398 N.D. 62) Benzo(k)fluoranthene 36.14 252 620 N.D. 63) Benzo(a)pyrene 37.12 252 1896 N.D. 64) Indeno(1,2,3-cd)pyrene 0.00 276 0 N.D. 65) Dibenz(a,h)anthracene 0.00 278 0 N.D. 66) Benzo (g,h,i)perylene 0.00 276 0 N.D.
(#) = qualifier out of range (m) = manual integration 28682.D GCMS1126.M Mon Dec 10 12:10:16 2001 Page 2
NYC-WTC_000035221
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000018546
Laboratory report showing GC/MS calibration data for polycyclic aromatic hydrocarbons and deuterated standards.
1 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035700
Laboratory notes stating the GCMS scan of sample AD28901 revealed no unusual compounds.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035745
Laboratory notes indicating re-extraction is required due to low recovery and potential contamination.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035444
GCMS scan results for sample AD28800 dated December 16, 2001, showing no unusual compounds found.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035489
GCMS scan results for sample AD28857 dated December 16, 2001, detecting bis(2-Ethylhexyl)phthalate and noting low pH.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035717
Laboratory notes identifying potential laboratory contamination by specific esters in sample AD28899.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035737
Laboratory notes stating the GCMS scan of sample AD28862 revealed no unusual compounds.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder