NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
NYC-WTC_000035195–000035228Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document Library Search Compound Report
Data File : C:\HPCHEM\l\DATA\DEC0401\28689.D Vial: 14 Acq On : ,5 Dec 2001 1:04 am Operator: 209 GALOS Sample : gc/ms 11/24 Inst : GC/MS 209 Mise : Multiplr: 1.00 MS Integration Params: LSCINT.P
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 11 Hexatriacontane Concentration Rank 15
R.T. EstConc Area Relative to ISTD R.T.
35.42 0.55 ug/1 81037 Perylene-dl2 37.13
Hit# Of 5 Tentative ID MW MolForm CAS# Qual
1 Hexatriacontane 507 C36H74 000630-06-8 2 Pentatriacontane 493 C35H72 000630-07-9 3 Dotriacontane 451 C32H66 000544-85-4 4 Tetratetracontane 619 C44H90 ___ ___ 007098-22-8 83 Abundance i 7 Scan 3309 (35.421 mln): 28689.D (-) m/z 57.00 100.00%
85 5000
MJ.4..4"11141,16.207 35.00 35.20 35.40 35.60 35.80
miz-> 50 100___ 150 200 m/z 43.00 74.26% 250 300 350 400 450 Abundance #74635: Hexatriacontane 57
5000 85 35.00 35.20 35.40 35.60 35.80 m/z 71.10 74.09% i ,113,141‘T 11PT+T 196 225 253 281 miz->__ 50 100 150 200 250 300 350 400 450 Abundance #587-3: Pentatriacontane 57 A A 444A04 -4-------- 35.00 35.20 35.40 35.60 35.80 5000 i l 85 m/z 85.05 50.57%
■ 11 I 113 141 169 197 225 m/z-? 50 100___150 200 250 ' 300 350 ' 400 450 Abundance #74490: Dotriacontane —A— AaAA,/.A,4 4 4-44 43 35.00 35.20 35.40 35.60 35.80 m/z 41.05 25.36% 71 5000-
miz-? T 50 Q7 I 127 155 183 ...... ... 100. . 150 200 250 300 350 379, 407,450 400 450 wumM/Lnha 35.00 35.20 35.40 35.60 35.80
28689.D GCMS1126.M Mon Dec 10 10:19:48 2001 Page 11
NYC-WTC_000035212
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000018546
Laboratory report showing GC/MS calibration data for polycyclic aromatic hydrocarbons and deuterated standards.
1 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder