NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
NYC-WTC_000035026–000035043Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document Library Search Compound Report
Data File : C:\HPCHEM\1\DATA\DEC0401\28688.D Vial: 6 Acq On 4 Dec 2001 5:15 pm Operator: 209 GALOS Sample : gc/ms 11/24 Inst : GC/MS 209 Misc Multiplr: 1.00 MS Integration Params: LSCINT.P
Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 7 Nonadecane Concentration Rank 4
R.T. EstConc Area Relative to ISTD R.T.
31.66 1.07 ug/l 214668 Chrysene-d12 33.04
Hit# of 5 Tentative ID MW MolForm CAS# Qual
1 Nonadecane 268 C19H40 000629-92-5 1 2 Heptadecane, 9-octyl- 352 C25H52 007225-64-1 1 3 Tetracosane 338 C24H50 000646-31-1 9 G - lllCl.11yl - V V1:1VV - oo - 7 I Scan 2899 (31.662 min): 28688.D (-) z 57.00 100.00%
5000.1 I I I 85
113 31.40 31.60 31.80 32.00 141 169 197 239 267 m/z 43.05 71.98% 0 100 120 140 160 180 200 220 240 260 #71949: Nonadecane
85 31.40 31.60 31.80 32.00 m/z 71.05 68.94% 113 141 169 224 268 0 100 120 140 160 180 200 220 240 260 #49558: Heptadecane, 9-octyl-
31.40 31.60 31.80 32.00 85 m/z 85.05 44.75%
113 141 169 239 310 352 0 100 120 140 160 180 200 220 240 #73543: Tetracosane 31.40 31.60 31.80 32.00 m/z 41.05 23.53%
1131 4. 155 N 33 T 120 140 160 180 340 31.40 31.60 31.80 32.00
28688.D GCMS1126.M Thu Dec 06 13:23:19 2001 Page 7
NYC-WTC 000035038
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088346
Laboratory report documenting GC/MS analysis of environmental sample AD23270 conducted on October 15, 2001.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder