NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
NYC-WTC_000035008–000035025Folder label: “GCMS X 11/24/01 A 12/4/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
LSC Report - Integrated Chromatogram
File C:\HPCHEM\l\DATA\DEC0401\28692.D Operator 209 GALOS Acquired 5 Dec 2001 5:56 am using AcqMethod GCMS1126 Instrument GC/MS 209 Sample Name: gc/ms 11/24 Mise Info : Vial Number: 19 Quant File :GCMS1126.RES (RTE Integrator) Abundance TIC: 28692.D 15.32 2500000
2000000
11.71 1500000
1000000
500000
0- > r । i . . i । i . । ( ............ —..................... Il Time-> 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00’ 19.00 Abundance TIC: 28692.D 20 59 2500000 25.00
2000000
33.04 1500000
1000000
29.44 500000 ? 30.08 31.57
0- ______ _____________________ 25.15______ 27.01 । 2869 3063 , 31.66 - PA- 32266 8333. Time-> 20.00 21.00 22.00 23.00 24.00 25.00 26.00 27.00 28.00 29.00 30.00 31.00 32.00 33 00 Abundance TIC: 28692.D
2500000
2000000
1500000
1000000 37.13
500000
34.53 35.42 0- T. T Tr ' l ' fT Time-> 34.00 35.00 3600 37.00 38.00 39.00 40.00 41.00 42.00 43.00 44.00 45.00 46.00 47.00 28692.D GCMS1126.M Thu Dec 06 12:39:09 2001
NYC-WTC_000035013
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034311
Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088346
Laboratory report documenting GC/MS analysis of environmental sample AD23270 conducted on October 15, 2001.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035000
Laboratory report detailing GCMS scan results for sample AD28680, noting phthalate detection and recovery rates.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034781
Laboratory analyst notes on GCMS scan results and recovery rates for sample AD28652 analyzed in early December 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034946
Laboratory report detailing GCMS scan results for sample AD28650, noting phthalate detection and low pH.
Filed in the same folder
NYC-WTC_000034947
Document containing unreadable text or corrupted data from the Department of Environmental Protection archives.
Filed in the same folder
NYC-WTC_000034949
Form detailing Method 508 parameters and sample volume information for environmental testing procedures.
Filed in the same folder
NYC-WTC_000034954
Reference data sheet listing concentrations of volatile organic compounds detected in sample AD28662.
Filed in the same folder
NYC-WTC_000034958
Calibration report showing recovery percentages for various chemical standards used in the GCMS analysis.
Filed in the same folder