NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Laboratory report documenting GCMS analysis of sample AD28430 conducted on December 6, 2001.
NYC-WTC_000034311–000034330Folder label: “GCMS X 11/21/01 A 11/27 - 11/28/01”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Library Search Compound Report Data File C:\HPCHEM\l\DATA\DEC0401\28430.D Vial: 12 Acq On 4 Dec 2001 11:06 pm Operator: 209 GALOS Sample gc/ms 11/24 Inst : GC/MS 209 Mise : Multiplr: 1.00 MS Integration Params: LSCINT.P Quant Method : C:\HPCHEM\1\METHODS\GCMS1126.M (RTE Integrator) Title : 209 625/TCLP calibration table Library : C:\DATABASE\NBS75K.L ********************************************************************* Peak Number 5 Octadecanoic acid, 2-methylpro Concentration Rank 2 R.T. EstConc Area Relative to ISTD R.T. 31.57 5.37 ug/1 1337960 Chrysene-dl2 33.04 Hit# of 5 Tentative ID MW MolForm CAS# Qual
1 Octadecanoic acid, 2-methylpropyl e 340 C22H4402 000646-13-9 66 2 Butyl tetradecanoate (myristate) 284 C18H3602 000000-00-0 64 3 Octadecanoi /acid, butyl ester 340 C22H4402 000123-95-5 45 4 2-Methyl-N/ -tridecene 196 C14H28 018094-01-4 27 Abundance ( Scan 2890 (31.572 min): 28430.D (-) m/z 56.00 100.00% 55
5000 41 73
1411114 129 171185200 227241 27 | tt ( rrt-rj-^n II‘"u1011un"0T‘T)’ - 285 311 340 JL ' I ' ' ' 31.20 31.40 31.60 31.80 32.00 m/z 57.00 52.96%
k m/z-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Abundance #48214: Octadecanoic acid, 2-methylpropyl ester 57
5000 T 1 1 1 1 31.20 31.40 31.60 31.80 32.00 285 m/z 43.05 46.17%
.k 73 97, 129 66 267 | " ' I' ■ 1 11 111 j ii ii|' rp 185_____ 241 [ l * 11 i ■ 111 > i ■ 11 111 11 i 111111 11 p 11 u| 111 11 rr 11111 340 —..... I" mlz-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Abundance #40186: Butyl tetradecanoate (myristate) 56
11 I ' 31.20 31.40 31.60 31.80 32.00 5000 m/z 41.05 39.20% 229 73 211 —11... ... 185 7 —mm 129 284 ” ■ i ■ 11 ri i r| i 11 r| । ri 11 >> । . j n t q cm > p > । . mz-> 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Abundance #73570: Octadecanoic acid, butyl ester 55 31.20 31.40 31.60 31.80 32.00 m/z 55.00 32.17%
5000 285 340 73 267 129 185 m/z—> " i" 40 60 L *11 80 7111... I 241 > rf i n r 111' 11111 111‘1‘111111111111110111/IITT 100 120 140 160 180 200 220 240 260 280 300 320 340 I ..... .............. 31.20 31.40 31.60 31.80 32.00
28430.D GCMS1126.M Wed Dec 05 08:19:43 2001 Page 5
NYC-WTC_000034322
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000035072
Laboratory report noting TurboVap contamination and low recovery rate for sample AD28678.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035089
Laboratory report noting TurboVap contamination with recovery data for sample AD28693.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034971
Blank test results confirming no detectable contaminants above method detection limits for sample AD28662.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035153
Laboratory report noting TurboVap contamination and recovery data for sample AD28663.
1 shared topics · Same agency, volume and box · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035008
Laboratory report detailing GCMS scan results for sample AD28669, noting phthalate detection and recovery rates.
1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034347
Laboratory report documenting GCMS analysis of sample AD28471 conducted on December 6, 2001.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
1 shared topics · Same agency, volume and box · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035026
Laboratory report noting di-n-butylphthalate detection and TurboVap contamination with recovery data for sample AD28688.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088000
Laboratory report documenting GC/MS analysis of sample AD23124 conducted on October 12, 2001.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000035052
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28691.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035135
Laboratory report noting di-n-butylphthalate detection and low pH with recovery data for sample AD28694.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035171
Laboratory report noting low recovery rate and TurboVap contamination for sample AD28677.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035106
Laboratory report noting recovery data and acceptance range issues for sample AD28695.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035115
Laboratory report noting TurboVap contamination and recovery data for sample AD28664.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000088098
Laboratory report documenting GC/MS analysis of sample AD23261 conducted on October 12, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000034154
Single page of raw GCMS data or header information from samples tested in late November 2001.
Filed in the same folder
NYC-WTC_000034155
Technical data sheet recording instrument parameters and calibration details for GCMS Method 508 analysis conducted in November 2001.
Filed in the same folder
NYC-WTC_000034156
Instrument sequence log listing calibration standards and sample IDs processed between November 26 and 30, 2001.
Filed in the same folder
NYC-WTC_000034160
Laboratory report of a method blank analysis for sample AD28263 conducted on November 26, 2001.
Filed in the same folder
NYC-WTC_000034168
Laboratory report of GCMS calibration data for sample AD28263 conducted on November 26, 2001.
Filed in the same folder