GCMS calibration table for TCLP analysis, May 2002

Machine-extracted title · confidence 90%

Calibration table and response data for TCLP volatile organic analysis using Method GCMS0501 on sample AE09578 analyzed in May 2002.

NYC-WTC_000023327–000023334

Folder label: “GCMS X 5/8/02 A 5/9/02

Page image
Scanned page image, NYC-WTC_000023328
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Data File C:\HPCHEM\1\DATA\MAY0 3 02\9578.D Vial: 51 Acq On 5 May 2002 5:01 pm Operator: Sample GC/MS SCAN 4/23 Inst : 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: May 7 14:57 2002 Quant Results File: GCMS0501.RES Quant Method : C:\HPCHEM\1\METHODS\GCMS0501.M (RTE Integrator) Title : 209 625/TCLP calibration table Last Update : Wed May 01 10:40:31 2002 Response via : Initial Calibration DataAcq Meth : GCMS0501

Compound R.T. Qlon Response Cone Unit Qvalue 3 5) Anthracene 25.63 178 312 N.D. 36) Di-n-butylphthalate 27.55 149 11804 0.27 ug/1 98 37) Fluoranthene 0.00 202 0 N.D. 3 9) Pyrene 0.00 202 0 N.D. 40) Butylbenzylphthalate 0.00 149 0 N.D. 41) Benzo(a)anthracene 33.63 228 1941 N.D. 42) Bis(2-ethylhexyl)phthalate 33.85 149 2989 N.D. 43) Chrysene 33.63 228 1941 N.D. 45) Di-n-Octylphthalate 0.00 149 0 N.D. 46) Benzo(b)fluoranthene 0.00 252 0 N.D. 47) Benzo(k)fluoranthene 0.00 252 0 N.D. 48) Benzo(a)pyrene 37.86 252 2179 N.D. 49)- Indeno (1,2,3-cd) pyrene 0.00 276 0 N.D. 5 0) Dibenz(a,h)anthracene 0.00 278 0 N.D. 51) Benzo(g,h,i)perylene 0.00 276 0 N.D.

(#) = qualifier out of range (m) = manual integration 9578.D GCMS0501.M Tue May 07 14:58:23 2002 Page 2

NYC-WTC_000023328

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000023328Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →