NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Laboratory report of gas chromatography mass spectrometry blank analysis for volatile organic compounds conducted on May 9, 2002.
NYC-WTC_000023207–000023215Folder label: “GCMS X 5/8/02 A 5/9/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
User: Galos, Marie Westchester Dept, of Labs & Research Date: 05/10/2002 Time: 14:42:25
Sample: AE08430 Analysis: $B1GCMS BlankI for GCMS Scan Units: ug Started: 5/9/20 00:03 Ended: 5/9/20 00:03 Analyst: MG Result source: manual entry Page: 1
Component Namr Viol Result MDL 1 1 n-Nitrosodimethylamine__ < MDL 2.0 2 bis(2-Chloroethyl)ether _____ < MDL 2.0 3 1,3-Dichlorobenzene < MDL 2.0 1,4-Dichlorobenzene_______ < MDL 2.0 5 - 1,2-Dichlorobenzene_______ < MDL 2.0 6 ! 2,2'-oxybis(1-Chloropropane) < MDL 2.0 7 n-Nitrosodi-n-propylamine < MDL 2.0 8 1Hexachloroethane ------------------------------------------------------------------- < MDL 2.0 9 Nitrobenzene < MDL 2.0 10 Isophorone < MDL 2.0 11 bis(2-Chloroethoxy)methane < MDL 2.0 17 ; 1,2,4-Trichlorobenzene < MDL 2.0 13 Naphthalene______________ < MDL 2.0 14 Hexachlorobutadiene______ < MDL 2.0 15 2-Chloronaphthalene______ < MDL 2.0 16 * Dimethylphthalate_________ < MDL 2.0 1 / 12,6-Dinitrotoluene_________ < MDL 2.0 18 Acenaphthylene___________ < MDL 2.0 19 Acenaphthene < MDL 2.0 20 2,4-Dinitrotoluene_______ < MDL 2.0 21 Diethylphthalate < MDL 2.0 22 4 Chlorophenylphenylether < MDL 2.0 23 Fluorene < MDL 2.0 24 Azobenzene < MDL 2.0 25 n Nitrosodiphenylamine < MDL 2.0 26 4-Bromophenylphenylether < MDL 2.0 27 Hexachlorobenzene < MDL 2.0 ‘28 Phenanthrene < MDL 2.0 29 Anthracene________ < MDL 2.0 30 Di-n-butylphthalate < MDL 2.0 31 Fluoranthene < MDL 2.0 132 Pyrene ~ < MDL 2.0 33 I Butylbenzylphthalate < MDL 2.0 . 34'' Benzo(a)anthracene < MDL 2.0 35 bis(2-Ethylhexyl)phthalate < MDL 2.0 36 Chrysene______________ < MDL 2.0 37 Di-n-octylphthalate < MDL 2.0 38 Benzo(b)fluoranthene < MDL 2.0 39 3 Benzo(k)fluoranthene < MDL 2.0 40 Benzo(a)pyrene < MDL 2.0 41 jlndeno[1,2,3-cd)pyrene < MDL 2.0 42 Dibenz(a,h)anthracene < MDL 2.0 43 | Benzo(g,h,i)perylene < MDL 2.0
NYC-WTC_000023207
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000023171
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023122
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023148
Calibration table listing response factors for deuterated standards used in TCLP analysis on May 5, 2002.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000023076
GCMS calibration table and instrument data for TCLP analysis recorded on May 5-7, 2002.
1 shared topics · Same agency, volume and box · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044758
Quality control blank analysis for GCMS showing non-detect results for semi-volatile organic compounds with detection limits of 2.0 µg, completed April 25, 2002.
1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043164
Laboratory report for DEP Box 25 showing GCMS blank analysis of sample AE09450 with semi-volatile organic compounds below detection limits from May 3, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043646
Laboratory report documenting a GC/MS blank run to check for contamination in the analytical system on May 6, 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043124
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE09396 with unknown compounds and surrogate data from May 9, 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000048695
Calibration table listing results for various organic compounds including nitrosamines and dichlorobenzenes from April 2002.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000049302
Laboratory report showing blank analysis results for sample AE08839 with various compounds below detection limits.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043036
Ten-page laboratory report showing GCMS blank analysis results for volatile organic compounds with values below detection limits.
1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043112
Laboratory report for DEP Box 25 showing GCMS analysis of sample AE09395 with unknown compounds and surrogate data from May 9, 2002.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000047955
GCMS blank analysis report for sample AE08209 listing volatile organic compounds from April 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043547
Laboratory report documenting a GC/MS blank run to check for contamination in the analytical system on May 6, 2002.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000047082
DEP laboratory report showing GCMS blank analysis results for sample AE07486 conducted on April 19, 2002.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043646
Laboratory report documenting a GC/MS blank run to check for contamination in the analytical system on May 6, 2002.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000044783
Laboratory report showing blank sample analysis results for volatile organic compounds using gas chromatography-mass spectrometry.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000043036
Ten-page laboratory report showing GCMS blank analysis results for volatile organic compounds with values below detection limits.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000022961
Department of Environmental Protection administrative record sheet for World Trade Center site activities dated May 2002.
Filed in the same folder
NYC-WTC_000022962
Fragmentary record containing a document identifier and date from the DEP GCMS analysis series.
Filed in the same folder
NYC-WTC_000022965
Laboratory report of a GCMS blank run conducted on May 14, 2002, showing non-detect results for various compounds.
Filed in the same folder
NYC-WTC_000022990
Laboratory report documenting GCMS calibration verification analysis conducted on May 14, 2002.
Filed in the same folder
NYC-WTC_000022994
Laboratory report of GCMS reference standard analysis conducted on May 14, 2002, showing recovery percentages.
Filed in the same folder