NYC-WTC_000009629–000009640Folder label: “GCMS X 1/14/02 A 3/4/02”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Quantitation Report (QT Reviewed)
Data File : C:\HPCHEM\l\DATA\FEB1502\1137.D Vial: 10 Acq On : 16 Feb 2002 12:12 am Operator: 209 GALOS Sample : gc/ms scan 1/16 Inst : GC/MS 209 Mise Multiplr: 1.00 MS Integration Params: GOOFY.P Quant Time: Mar 4 15:01 2002 Quant Results File: GCMS0208.RES
Quant Method : C:\HPCHEM\1\METHODS\GCMS0208.M (RTE Integrator) Title : 209 625/TCLP calibration table .' p Last Update : Wed Feb 27 11:30:15 2002 AP Response via : Initial Calibration 1 DataAcq Meth : GCMS0208 CN l
Internal Standards R.T. Qlon Response Cone Units Dev(Min)
1) 1,4-Dichlorobenzene-d4 12.33 152 438597 20.00 ug/1 -0.02 10) Naphthalene-d8 15.97 136 1676800 20.00 ug/1 -0.02 17) Acenaphthene-diO 21.29 164 900901 20.00 ug/1 -0.02 29) Phenanthrene-diO 25.74 188 1283057 20.00 ug/1 -0.02 38) Chrysene-dl2 33.81 240 909628 20.00 ug/1 -0.03 44) Perylene-dl2 38.09 264 654677 20.00 ug/1 -0.03
System Monitoring Compounds 37) 2,4-DDD 30.81 235 55882 4.17 ug/mL 0.31 Spiked Amount 5.000 Recovery = 83.40%
Target Compounds Qvalue 2) N-nitroso-dimethyl amine 0.00 74 0 N.D. 3) bis(2-Chloroethyl)ether 0.00 93 0 N.D. 4) 1,3-Dichlorobenzene 0.00 146 0 N.D. 5) 1,4-Dichiorobenzene 0.00 146 0 N.D. 6) 1,2-Dichlorobenzene 0.00 146 0 N.D. 7) 2,2'-oxybi s(1-Chloropropan 0.00 45 0 N.D. 8) N-Nitroso-di-n-propylamine 0.00 70 0 N.D. 9) Hexachloroethane 0.00 117 0 N.D. 11) Nitrobenzene 0.00 77 0 N.D. 12) 1sophorone 0.00 82 0 N.D. 13) bis(2-Chloroethoxy)methane 0.00 93 0 N.D. 14) 1,2,4-Trichlorobenzene 0.00 180 0 N.D. 15) Naphthalene 16.03 128 799 N.D. 16) Hexachlorobutadiene 0.00 225 0 N.D. 18) Hexachlorocyclopentadiene 0.00 237 0 N.D. 19) 2-Chloronaphthalene 0.00 162 0 N.D. 20) Dimethylphthalate 0.00 163 0 N.D. 21) 2,6-Dinitrotoluene 0.00 165 0 N.D. 22) Ac enapht hylene 0.00 152 0 N.D. 2 3) Acenaphthene 0.00 153 0 N.D. 24) 2,4-Dinitrotoluene 0.00 165 0 N.D. 25) Diethylphthalate 22.77 149 381 N.D. 26) 4-Chlorophenyl-phenylether 0.00 204 0 N.D. 27) Fluorene 0.00 166 0 N.D. 28) Azobenzen/ 1,2-Diphenylhyd 0.00 77 0 N.D.
(#) = qualifier out of range (m) = manual integration 1137.D GCMS0208.M Mon Mar 04 15:02:18 2002 Page 1
NYC-WTC_000009629
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000004149
Large multi-page laboratory data sheet containing sample analysis results and metadata for DEP GCMS records from January to February 2002.
1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000018546
Laboratory report showing GC/MS calibration data for polycyclic aromatic hydrocarbons and deuterated standards.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034180
Laboratory report detailing GCMS analysis of sample AD28269 conducted on November 30, 2001.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034830
Laboratory analyst notes on GCMS scan results and recovery rates for sample AD28666 analyzed in early December 2001.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034331
Laboratory report documenting GCMS analysis of sample AD28427 conducted between November 21 and 26, 2001.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000033800
Analytical commentary for sample AD28157 dated November 29, 2001, noting no unusual compounds but low recovery rates for LCS standards.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034988
Laboratory report noting contamination from the TurboVap concentrator and recovery rates for sample AD28662.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000017833
Laboratory report detailing gas chromatography-mass spectrometry analysis of sample AD30351 conducted on January 10, 2002.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000035195
Laboratory report noting low pH and TurboVap contamination with recovery data for sample AD28689.
1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000017748
Laboratory report detailing gas chromatography-mass spectrometry analysis of sample AD30357 conducted on January 10, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000034213
Laboratory report detailing GCMS analysis of sample AD28271 conducted on December 6, 2001.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000017675
Laboratory report detailing gas chromatography-mass spectrometry analysis of sample AD30251 conducted on January 9, 2002.
1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000009686
Laboratory file showing GC/MS calibration response factors for surrogate compounds from February and March 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009670
Laboratory file showing GC/MS calibration response factors for surrogate compounds from February and March 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000009650
Calibration table page listing internal standards and response factors for GCMS analysis.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052666
Calibration record for GC/MS instrument 209 used in TCLP testing, listing standard compounds and response factors from February 14, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000016407
Laboratory report documenting gas chromatography-mass spectrometry analysis of environmental sample AD31278 conducted on February 25, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000052875
Laboratory report documenting gas chromatography-mass spectrometry analysis of sample AE01332 conducted on February 27, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000009547
Administrative record from DEP Box 14 covering the period of January to March 2002 regarding World Trade Center environmental activities.
Filed in the same folder
NYC-WTC_000009548
Header page from a GCMS document showing surrogate recovery and pH data.
Filed in the same folder
NYC-WTC_000009554
Calibration table listing internal standards and response factors for GCMS Method 508.
Filed in the same folder
NYC-WTC_000009557
GCMS blank analysis for sample AE00938 listing compounds below detection limits.
Filed in the same folder
NYC-WTC_000009566
Calibration standard analysis for sample AE00938 showing quantitative results for organic compounds.
Filed in the same folder