DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140172Machine-extracted title Lab reportSummary EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
Air sampling cannot be used in lieu of a complete removal of the
asbestos-contaminated dusts.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140186Machine-extracted title Lab reportSummary EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
Evaluation of Three Cleaning Methods for Removing Asbestos from Carpet: Determination of
Airborne Asbestos Concentrations Associated with Each Method, US EPA Risk Reduction
Engineering Laboratory,
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140276Machine-extracted title Lab reportSummary Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
*
Evaluation of Three Cleaning Methods for Removing Asbestos from Carpet: Determination of
Airborne Asbestos Concentrations Associated with Each Method, US
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140265Machine-extracted title Lab reportSummary Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
Even the wet-extraction
, HEPA vacuums did n* t remove all of die asbestos^ only about 60%
Thus, the same or similar levels of asbestos could rernam in the carpets as their were before
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA/NYC Indoor Air/Approach Request FEMA
NYC-WTC_000141571Machine-extracted title FormSummary Request outlining specific actions including HEPA vacuum distribution and airborne asbestos testing for residents.
b) Testing for airborne asbestos within residences or building areas.
DEP Hard Copies (68 Boxes) / DEP Box 05 / SCOPES OF WORK IN DOOR AIR & CLEANING
NYC-WTC_000140511Machine-extracted title FormSummary Draft document outlining regulations and assistance programs for residential cleaning following the World Trade Center collapse.
The assistance will include various options,
including the cleaning within apartments and common space*' In licensed asbestos contractors with
follow-up asbestos sampling, asbestos air sampling onl^; and
DEP Hard Copies (68 Boxes) / DEP Box 05 / SCOPES OF WORK IN DOOR AIR & CLEANING
NYC-WTC_000140517Machine-extracted title Permit applicationSummary Departmental comments and requests for clarification regarding cleaning triggers, clearance levels, and supervision requirements.
The assistance will include various options,
including the cleaning within apartments and common spaces by licensed asbestos contractors with
follow-up asbestos sampling, asbestos air sampling only, and
DEP Hard Copies (68 Boxes) / DEP Box 05 / SCOPES OF WORK IN DOOR AIR & CLEANING
NYC-WTC_000140597Machine-extracted title Chain of custodySummary Contractual agreement establishing an independent firm to monitor debris cleanup and conduct air sampling.
The assistance will include various options, including the cleaning within apartments
and common spaces by licensed asbestos contractors with follow-up asbestos sampling, asbestos
air sampling only, and
DEP Hard Copies (68 Boxes) / DEP Box 05 / SCOPES OF WORK IN DOOR AIR & CLEANING
NYC-WTC_000140603Machine-extracted title Chain of custodySummary Contract establishing requirements for third-party asbestos monitoring and air sampling in residential buildings.
NYC 9/11 Public Portal Document
ASBESTOS PROJECT MONITOR AND AIR SAMPLING CONTRACT
A.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140045Machine-extracted title Chain of custodySummary Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
The asbestos is caught on a filter, and then the filter is sent to
the lab for testing.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140055Machine-extracted title Chain of custodySummary Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Because data clearly
demonstrate that a cleaned surface, even in an asbestos-contaminated building, will only have 86
to 320 s/cm’ asbestos (see Table 2) there is no reason why the cleanup standard
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140090Machine-extracted title Chain of custodySummary Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
The asbestos is caught on a filter, and then the filter is sent to
the lab for testing.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140100Machine-extracted title Chain of custodySummary Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Because data clearly
demonstrate that a cleaned surface, even in an asbestos-contaminated building, will only have 86
to 320 s/cm^ asbestos (see Table 2) there is no reason why the cleanup standard
DEP Hard Copies (68 Boxes) / DEP Box 05 / FEMA SEMO
NYC-WTC_000140966Machine-extracted title Chain of custodySummary Form authorizing the City of New York to proceed with obligations related to FEMA emergency management programs for WTC cleanup.
The assistance will include various options, including the cleaning within apartments and
common spaces by licensed asbestos contractors follow-up asbestos sampling, asbestos air
sampling
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140152Machine-extracted title Lab reportSummary EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Because data clearly
demonstrate that a cleaned surface, even in an asbestos-contaminated building, will only have 86
to 320 s/cm’ asbestos (see Table 2) there is no reason why the cleanup standard
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA/NYC Indoor Air/Approach Request FEMA
NYC-WTC_000141551Machine-extracted title Lab reportSummary Draft plan describing agency roles and near-term actions to support residents and workers in Lower Manhattan.
b) Testing for aiibome asbestos within residences or building areas.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140147Machine-extracted title Lab reportSummary EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Levels of 1% or less could present a risk where
there is enough activity to sti- up soil and cause
asbestos fibers to become airborne.’
DEP Hard Copies (68 Boxes) / DEP Box 05 / '$ Matrix, etc See FEMA
NYC-WTC_000141202 Memo or letter(Scope A) 15,000 units to be
(Asbestos cleaned.
DEP Hard Copies (68 Boxes) / DEP Box 05 / SCOPES OF WORK IN DOOR AIR & CLEANING
NYC-WTC_000140468Machine-extracted title FormSummary Contract addendum defining personal protective equipment and training requirements for HVAC professionals inspecting WTC dust.
The primary purpose of the asbestos certification requirement is to be able to identify
asbestos-containing materials and asbestos-related hazards in order to avoid the disturbance of
asbestos-containing
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA Cate Jenkins
NYC-WTC_000140187Machine-extracted title Lab reportSummary EPA memorandum on wipe sampling methods for asbestos in Lower Manhattan buildings, resuspension projections, and cancer risk estimates from WTC dust exposure.
Mugdan, Walter (December 19, 2001) Regional Asbestos Coordinators and National
Asbestos Coordinators Meeting for December, Conference call.
18. Chatfield, E. J., and Kominsky, J.