DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141074Machine-extracted title Lab reportSummary Announcement regarding the awarding of contracts for residential dust cleanup and testing in lower Manhattan after the World Trade Center attacks.
counting the number of asbestos fibers found.
DEP Hard Copies (68 Boxes) / DEP Box 05 / M.G: EPA INDOOR AIR WORKING GROUP MTGS.
NYC-WTC_000140751Machine-extracted title Lab reportSummary Summary table of asbestos fiber concentrations in air and surface wipe samples from Liberty Street and background locations.
4
Background Study - Summary for Asbestos
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000140996Machine-extracted title UnclassifiedSummary Press release announcing joint EPA and OSHA environmental monitoring data collection at the World Trade Center site.
asbestos-containing material.
DEP Hard Copies (68 Boxes) / DEP Box 05 / FEMA SEMO
NYC-WTC_000140913Machine-extracted title UnclassifiedSummary Report detailing over 6,200 air and dust samples analyzed for asbestos and other contaminants at the World Trade Center.
The air samples from inside the buildings showed no elevated levels of
asbestos, however low levels of asbestos and fibrous glass were found in the settled dust in some
of the residential units, common
DEP Hard Copies (68 Boxes) / DEP Box 05 / FEMA SEMO
NYC-WTC_000140928Machine-extracted title UnclassifiedSummary Report summarizing over 6200 air and dust samples analyzed for asbestos and other contaminants, along with data collection efforts by various agencies.
The air samples from inside the buildings showed no elevated levels of
asbestos, however low levels of asbestos and fibrous glass were found in the settled dust in some
of the residential units, common
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141011Machine-extracted title UnclassifiedSummary Statement by EPA officials appearing before the New York State Environmental Protection Committee on November 1, 2001.
Keep in mind that the levels of asbestos we have found do not imply an
NYC-WTC_000141011
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141119Machine-extracted title Lab reportSummary EPA news summary dated October 14, 2001, regarding environmental monitoring data collected from the World Trade Center site.
One sample (bulk steel) contained 2.68% asbestos (chrysotile).
DEP Hard Copies (68 Boxes) / DEP Box 05 / FEMA SEMO
NYC-WTC_000140949Machine-extracted title UnclassifiedSummary Informational sheet details the voluntary program for cleaning homes and conducting air monitoring for asbestos and other contaminants.
NYC 9/11 Public Portal Document
of airborne asbestos testing, modified-aggressive and aggressive.
DEP Hard Copies (68 Boxes) / DEP Box 05 / '$ Matrix, etc See FEMA
NYC-WTC_000141294 Memo or letterestimates for
asbestos analysis.)
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141083Machine-extracted title UnclassifiedSummary EPA daily summary of environmental sampling and analysis for air, dust, water, and sediments at the World Trade Center site in October 2001.
children to re-enter school buildings after asbestos
removal activities.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141116Machine-extracted title UnclassifiedSummary EPA news summary dated October 16, 2001, regarding environmental monitoring data collected from the World Trade Center site.
children to re-enter school buildings after asbestos
removal activities.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141006Machine-extracted title UnclassifiedSummary Article reporting positive findings from a study of dust samples taken from Manhattan shortly after the September 11 attacks.
Questions
Ads & Flyers
EPA Press Releases
Pictures
Monitoring Summaries
New York City Area
Pentagon
Monitoring Data
Asbestos in Air
Asbestos in Bulk
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141114Machine-extracted title UnclassifiedSummary EPA daily summary of environmental sampling and analysis for air, dust, water, and sediments at the World Trade Center site in October 2001.
children to re-enter school buildings after asbestos
removal activities.
DEP Hard Copies (68 Boxes) / DEP Box 05 / B.Avaltroni EPA INDOOR AIR TASK FORCE
NYC-WTC_000140815Machine-extracted title UnclassifiedSummary Document detailing the methodology for identifying contaminants of concern and listing seven tentatively identified substances.
information on building collapses/fires
- Review (qualitative toxicity/concentration screen) of available sampling data
Status of COC List
1)7 contaminants tentatively identified:
Asbestos
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141002Machine-extracted title UnclassifiedSummary Press release announcing that eight contracts have been awarded for the downtown World Trade Center residential dust cleanup program.
EPA has
Organic
already begun testing homes for asbestos in air, and cleanups will begin this week.
DEP Hard Copies (68 Boxes) / DEP Box 05 / EPA WEB
NYC-WTC_000141033Machine-extracted title UnclassifiedSummary Fact sheet reporting that drinking water samples from lower Manhattan showed no asbestos or bacterial contamination.
Asbestos
was not detected in any of the samples, nor was any bacterial contamination.
DEP Hard Copies (68 Boxes) / DEP Box 05 / M.G: EPA INDOOR AIR WORKING GROUP MTGS.
NYC-WTC_000140743Machine-extracted title FormSummary Attendee list for the EPA Indoor Air Working Group meeting held at 290 Broadway on April 4, 2002.
• NYC’s cleaning efforts will concentrate on asbestos which they expect would also
NYC-WTC_000140743
DEP Hard Copies (68 Boxes) / DEP Box 05 / M.G: EPA INDOOR AIR WORKING GROUP MTGS.
NYC-WTC_000140643Machine-extracted title UnclassifiedSummary Documentation describing the methodology for identifying contaminants of concern using historical data and qualitative toxicity screens.
concentration screen) of available sampling data CD
3
Status of COC List
1) 7 contaminants tentatively identified:
Asbestos
DEP Hard Copies (68 Boxes) / DEP Box 05 / FEMA Equipment Requests Emergency Expenses
NYC-WTC_000141642Machine-extracted title Permit applicationSummary Map showing the condition of buildings at the World Trade Center site as of September 21, 2001.
EPA 2001 December 14 meeting):
• AHERA school re-entry standard for airborne asbestos (70 S/mm^)
• OSHA/EPA definition of ACM for bulk material (> 1% asbestos)
DEP Hard Copies (68 Boxes) / DEP Box 05 / M.G: EPA INDOOR AIR WORKING GROUP MTGS.
NYC-WTC_000140724Machine-extracted title UnclassifiedSummary Plan to test 15 new buildings for seven chemicals of concern including dioxin, lead, and asbestos.
buildings - and test for 7 identified chemicals of
concern; dioxin, lead, PAHs, ceramic fibers, fibrous glass, asbestos, and silica.