Beginning September 12“*, DEP has operated a network of outdoor (or “ambient”) fixed air monitors that have been used for monitoring asbestos levels. At this point there are monitors at 20 sites. Since September 11“*, we have had monitors at as many as 37 locations. The locations are shown on the map. The map and all sampling results to date from the sites shown on this map are on DEP’s website: www.nyc.gov/dep.

The samples are collected on filters and examined under PCM (Phase Contrast Microscopy) with a specific method developed by NIOSH. The PCM analysis counts fibrous particles, not necessarily only asbestos. PCM sample results are compared to the clearance/re-occupancy standard for indoor air following an asbestos abatement project. This standard is 0.01 fibers per cubic centimeter. Samples found to be above this standard are re-examined using TEM (Transmission Electron Microscopy). The TEM analysis identifies the type of particles and/or asbestos collected. TEM results are compared to the clearance/re-occupancy standard for indoor air in schools after an asbestos abatement project. This standard is 70 structures per square millimeter. In layman’s terms a “structure” is a fiber particle.

The standards used are for indoor air and are applied to the outside air as a conservative benchmark, since there is no standard for outdoor air.

Based on approximately 980 samples tested using PCM and 158 samples tested using TEM (16 tested above 70 - also 29 samples the filters were so clogged that a count of structures could not be made), public health experts are very confident that asbestos levels in ambient air outside of the restricted zone do not pose a threat to human health. Short-term exposure to abestos, even at levels much higher than 0.01, carries an extremely low risk of causing asbestos-related illness.

DEP’s monitors are all outdoor. At this point, there are no stationary monitors in place within buildings. Judging from phone calls, conversations, and comments at community meetings, there are many individuals who are not clear on the division of clean-up and testing responsibilities. I would like to re-state a few basic facts regarding cleanup.

Before allowing occupants in any residential or commercial building near the Ground Zero [MORE SPECIFIC?], the City required building owners to take these steps:

o Assess the building’s structural strength and stability using qualified professionals; o Restore gas and electrical service; o Restore building water service, including flushing, re-filling and cleaning roof tanks as necessary; o Assess the presence of hazardous materials such as asbestos, and remediate as required under applicable regulations using qualified professionals; o Inspect, clean and repair mechanical and HVAC systems.

Although city, state and federal agencies have provided oversight and guidance, “indoor

CITY_21MC100_008702030

NYC-WTC_000456038

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000456038Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →