Abatement specifications, exterior sealants, P.S. 92M

Machine-extracted title · confidence 45%

CoC/documents for asbestos-containing exterior sealant/caulking materials for DDC school task force, June 2001.

NYC-WTC_000455928–000456011
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SECTION 02082 the New York State Education Department requires public school final air clearance be performed and analyzed using the TEM method, as well as in nonpublic school asbestos projects.

A. Air Sampling and Analysis:

Section 763.90 of AHERA and the New York State Education Department requires that public schools accomplish final air sampling and analysis of all removal, encapsulation, or enclosure projects by using the transmission electron microscopy (TEM) method. Under AHERA, nonpublic schools must also use TEM for final air analysis. Note that no final air clearance is required for small-scale, short-duration O & M projects, unless there is a break in the containment.

B. The TEM Method for Final Air Clearance:

The TEM method involves the collection of at least five samples inside the work area, five samples representative of air outside of the work area collected at the same time as the indoor samples, and three quality control samples. The air samples must be collected using “aggressive” methods of artificially disturbing the air in the work are before sampling, as described in Appendix A, Section III (B)(7)(d) of the AHERA Rule. The volume of air drawn for each of the five samples collected within the functional space must be equal to or greater than 1,199 L of air for a 25mm filter or equal to or greater than 2,799L of air for a 37mm filter. If the average result of the five samples collected inside the work area meets an average of 70 structures per square millimeter (70s/mm2), the response action is considered complete.

The response action may also be considered complete when the average concentration of asbestos of the five air samples collected within the affected work area and analyzed by the TEM method is not statistically significantly different, as determined by the Z-test calculation described in Appendix A of AHERA, from the average asbestos concentration of five air samples collected outside the affected work area and analyzed in the same manner, and the average asbestos concentration of the three quality control samples is below 70s/mm2, the test is voided and resampling must be done. If the difference in average asbestos concentration between in and out samples is statistically significant, the contractor must reclean the work area and resampling must be done at the Contractor’s expense.

C. PCM Air Monitoring:

The phase contrast microscopy (PCM) method involves collecting at least five samples inside the work area by aggressive methods as described in Appendix A, Section III (B)(7)(d) of the AHERA Rule and having them analyzed on a PCM microscope. Unlike the TEM method, the PCM method does not call for the samples to be averaged; each sample stands on its own.

The clearance standard for PCM is 0.01 fibers per cubic centimeter of air (0.01 f/cc). If all five samples pass this standard, the response action is considered complete. If even one sample fails to pass the standard, the Contractor must reclean the area and resampling must be done.

1.27 TESTING LABORATORY SERVICES

A. "Air Sampling" shall mean the process of measuring the fiber content of a known volume of air

02082-40

CITY_21 MCI 00_014563896

NYC-WTC_000455967

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455967Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →