NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
20 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
NYC-WTC_000455886–000455921OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
The investigation of airborne levels during active cleaning activities should be conducted at the same 12 locations as were selected for the routine household or business activities investigation above. In cases where visible dust is NOT evident, residents or workers will be asked to NOT engage in cleaning activities for one week prior to this event. Due to the possibility that such activities might be associated with increased exposure to asbestos fibers, the cleaning activities should be performed not by the residents of the apartment, but by a trained staff member or consultant with appropriate health and safety training and wearing adequate personal protective equipment (PPE).
As before, both personal and stationary air samples will be collected. The personal air sample will be collected using a portable high-volume air sampler worn by the person performing active cleaning activities such as sweeping, vacuuming, and dusting. This activity will be conducted for a time period of approximately 2 hours. To the extent possible, the cleaning activities performed in each apartment or business will be standardized as follows:
Vacuuming. This will be done using the vacuum cleaner owned by the resident. If the resident does not own a suitable vacuum cleaner, then a vacuum will be provided. This will be a standard commercial cleaner, not a HEPA device. Vacuuming should be performed for approximately 40 minutes, and should cover carpets, rugs that a resident might normally vacuum.
Sweeping. This will be done using a straw or plastic broom. If possible, this will be a broom owned by the resident, but a broom may also be used. Sweeping should be done mainly on uncarpeted floors. Sweeping should be from the edges toward the center. If the sweeping generates a visible pile of dust or dirt, this should be sampled using the microvac method (SOP ASTM 5755-95), and the remainder picked up with a dust pan and discarded as IDW. Total time spent sweeping should be approximately 40 minutes.
Dusting. Dusting will be done with a clean dry rag provided. Dusting may be done on any surface that might normally be dusted by a resident, including table tops, counters, window sills, picture frames, lamp shades, etc. Total time spent dusting should be approximately 40 minutes.
The stationary air sampler will be a high volume pump located in the same central living area of the main apartment as was used during the routine activity investigation (above). The sampling time will be the same for the stationary sampler as for the personal sampler. To the extent feasible, pump flow rates will be adjusted to approach or exceed the target volumes specified in Appendix G.
In order to help quantify the impact of the activity (active cleaning) on asbestos levels in air, the stationary air monitor will also be used to collect a pre-activity and a post activity sample as well as the sample during the activity. The sampling duration for these samples should be approximately 3 hours. An example sampling scheme is summarized below:
CITY_21MC100_006387292
NYC-WTC_000455900
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
20 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
19 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418628
Draft NYC DOH environmental monitoring document relating to WTC collapse exposure fibers.
19 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
20 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
20 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
19 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
20 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
20 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241745
Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.
19 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139656
Forwarded spreadsheet compiling residential asbestos sampling results collected in November-December 2001, including Building 11 reoccupancy assessment.
13 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164960
Draft compilation of asbestos air samples collected from residential areas November-December 2001 by NYC DOH and ATSDR.
13 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000250451
Final draft of ambient and indoor dust evaluation protocol for WTC area.
7 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similar indexed content
NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
Similar indexed content
NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similar indexed content
NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
Similar indexed content
NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similar indexed content