NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

Chain-of-custody for WTC environmental samples

Machine-extracted title · confidence 42%

Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.

NYC-WTC_000436795–000436830
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

The investigation of airborne levels during active cleaning activities should be conducted at the same 12 locations as were selected for the routine household or business activities investigation above. In cases where visible dust is NOT evident, residents or workers will be asked to NOT engage in cleaning activities for one week prior to this event. Due to the possibility that such activities might be associated with increased exposure to asbestos fibers, the cleaning activities should be performed not by the residents of the apartment, but by a trained staff member or consultant with appropriate health and safety training and wearing adequate personal protective equipment (PPE).

As before, both personal and stationary air samples will be collected. The personal air sample will be collected using a portable high-volume air sampler worn by the person performing active cleaning activities such as sweeping, vacuuming, and dusting. This activity will be conducted for a time period of approximately 2 hours. To the extent possible, the cleaning activities performed in each apartment or business will be standardized as follows:

Vacuuming. This will be done using the vacuum cleaner owned by the resident. If the resident does not own a suitable vacuum cleaner, then a vacuum will be provided. This will be a standard commercial cleaner, not a HEPA device. Vacuuming should be performed for approximately 40 minutes, and should cover carpets, rugs that a resident might normally vacuum.

Sweeping. This will be done using a straw or plastic broom. If possible, this will be a broom owned by the resident, but a broom may also be used. Sweeping should be done mainly on uncarpeted floors. Sweeping should be from the edges toward the center. If the sweeping generates a visible pile of dust or dirt, this should be sampled using the microvac method (SOP ASTM 5755-95), and the remainder picked up with a dust pan and discarded as IDW. Total time spent sweeping should be approximately 40 minutes.

Dusting. Dusting will be done with a clean dry rag provided. Dusting may be done on any surface that might normally be dusted by a resident, including table tops, counters, window sills, picture frames, lamp shades, etc. Total time spent dusting should be approximately 40 minutes.

The stationary air sampler will be a high volume pump located in the same central living area of the main apartment as was used during the routine activity investigation (above). The sampling time will be the same for the stationary sampler as for the personal sampler. To the extent feasible, pump flow rates will be adjusted to approach or exceed the target volumes specified in Appendix G.

In order to help quantify the impact of the activity (active cleaning) on asbestos levels in air, the stationary air monitor will also be used to collect a pre-activity and a post activity sample as well as the sample during the activity. The sampling duration for these samples should be approximately 3 hours. An example sampling scheme is summarized below:

CITY_21MC100_011206002

NYC-WTC_000436809

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436809Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →