Site sampling general procedures, field investigation

Machine-extracted title · confidence 44%

Overview of standard operating procedures for collecting soil, water, sediment samples at various locations.

NYC-WTC_000455821–000455835
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

19. Collect the cold water directly in the sample container, taking care not to spill on the outside of the container or overfill container, and replace cover on the sample container. Samples for volatile organic analyses will have no air space in the sample vial prior to sealing. This is done by filling the vial such that there is a meniscus on top. Carefully slide the septum, Teflon side down, onto the top of the vial and cap the vial. Check for bubbles by turning the vial upside down and tapping it lightly. If bubbles appear, reopen the vial, remove the septum and add more sample (or resample). Replace the septum, recap and check for bubbles. Continue until vial is bubble-free. 20. 21. Return sample to sample cooler. 22. 23. Reattach water line that may have been disconnected ahead of treatment devise and reassemble screens and/or treatment systems that may have been removed.

6.14 Ambient Air (Sorbent Tube Method TOI or 102j

24. Be certain sample location is noted on Location Sketch (see Section 8.1). 25. 26. Set the flow rate* to the desired setting on the air pump. 27. 28. Label sorbent tube and fill out Sample Information Record and Chain of Custody Form. 29. 30. Connect the sorbent tube to pump using polyethylene tubing and set sorbent tube in breathing zone. (This can be accomplished by attaching the pump to a stake). 31. 32. Turn on pump and monitor the pump flow rate at half hour intervals during the duration of sampling. 33. 34. Turn off pump and disconnect the sorbent tube and check the pump flow rate. 35. 36. Place sorbent tubes in containers and place in cooler. 37. 38. Place all disposable personal protective equipment and disposable sampling equipment into a 55-gallon drum and store in a secure area (fenced, if possible).

* Flow rate is determined using a calculation contained in Method TOI or T02 based on the constituents of concern at the site.

eD1519\A0930701.doc 6-15

CITY_21MC100_009947940

NYC-WTC_000455835

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000455835Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →