Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
• Sampling Cartridge - Constructed from a 20-mm (I.D.) by 10-cm borosilicate
glass tube drawn down to a 7-mm (O.D.) open connection for attachment to the
pump by way of flexible tubing.
• Polyurethane Foam (PUF) Plugs - Cut into a cylinder, 22-mm (ED.) and 7.6-cm
long, fitted under slight compression inside the cartridge. Polyether type (density
0.0225 g/cm3). Plugs should be slightly larger in diameter than the internal
diameter of the cartridge. Pre-extracted PUF plugs and glass cartridges may be
obtained commercially.
• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate
seal to prevent pre- or post- sampling exposure to other potential sources of the
target analytes.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will
insert the PUF plug into the glass sample cartridge during pre-sampling
preparation.
• Flexible Tubing - Used to connect the cartridge assembly to the sampling pump.
• Sample Cartridge Shipping Containers - The analytical laboratory will provide
individually labeled containers that will be used to transport the sample cartridges
to the field location and back to the laboratory for analysis. This will include
aluminum foil wrapped around the cartridge and a glass jar large enough to hold
the cartridge.
• White Cotton Gloves - For handling the cartridges.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.
• High Flow Rotometer - 2.0 to 20.0 1pm
10.2.7 Polycyclic Aromatic Hydrocarbons (PAHs)
PAH samples will be collected using high-volume air samplers fitted with non-size
selective quartz fiber filters and sorbent cartridges. This approach, as described in EPA
Method TO-13 A, does not collect particulate matter representative solely of potential
inhalation exposure, but provides for a total of respirable and non-respirable PAHs.
Sorbent traps containing polyurethane foam (PUF) and XAD-2® resin in a “sandwich”
configuration. The General Metals Works (GMW) PS-1 high volume sorbent sampler (or
performance equivalent) located at each monitoring station will be operated at a flow rate
of 200 to 300 liters per minute with a sampling period of approximately 24 hours for a
resulting total air volume of approximately 288 ms - 432 ms. The filters and sorbent
cartridges will be solvent pre-cleaned and vacuum dried by the analytical laboratory. The
pre-cleaned filters and cartridges will be stored wrapped in aluminum foil (or otherwise
protected from light) in a Ziploc bag, and over wrapped with bubble wrap until they are
carefully installed on the sampler on site. At the conclusion of each sampling period, the
sample is recovered from the sampling train by placing the filter inside the glass
cartridge. The cartridge is then wrapped with aluminum foil and it is placed back into its
original shipping container, labeled, and transported to the analytical laboratory for
processing. The amount of air sampled through the filters and cartridges will be recorded
and the filter/cartridge set placed in an appropriately labeled container and shipped to the
laboratory for analysis. Equipment and supplies utilized with this sampling approach are
50