Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
as follows:
• High-Volume Sampler - General Metals Works model PS-1 (or performance
equivalent). Capable of pulling ambient air through the filter/sorbent cartridge at a
flow rate of approximately 200-300 1pm over a 24-hour sampling period.
• Sampling Module - Metal filter holder capable of holding a 102-mm circular
particle filter supported by a 16-mesh stainless-steel screen and attaching to a
metal cylinder capable of holding a 65-mm O.D. (60-mm I.D.) x 125-mm
borosilicate glass sorbent cartridge containing PUF and XAD-2® resin in the
“sandwich” configuration. To ensure air-tight seals, the filter holder is equipped
with inert sealing gaskets placed on either side of the filter and inert pliable
gaskets placed at either end of the glass sorbent cartridge.
• High-Volume Sampler Calibrator - Capable of providing multi-point resistance
for the highvolume sampler.
• Quartz Fiber Filter - 102 mm binderless quartz micro fiber filter. (Provided by
the laboratory, pre-cleaned and weighed.)
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal
diameter of the cartridge.
• XAD-2® Resin - Used to assemble the PUF/XAD-2 “sandwich” cartridges.
Supelco (or equivalent). Pre-cleaned and assembled by the analytical laboratory.
• White Cotton Gloves - For handling the filters and cartridges.
• Sample Cartridge Shipping Containers - The analytical laboratory will provide
individually labeled containers that will be used to transport the sample cartridges
to the field location and back to the laboratory for analysis. This will include
aluminum foil wrapped around the cartridge and a glass jar large enough to hold
the cartridge.
• 0-100” Magnehelic Gage.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.
10.2.8 Mercury (Total)
An iodated carbon trap is used to collect total mercury (particulate associated and vapor).
The samples are then analyzed using cold vapor atomic fluorescence (CVAFS). The
carbon trap is a proven and sensitive method for detecting trace ambient levels of
atmospheric mercury. To collect the mercury sample, a personal sampling pump will be
attached to the carbon trap and set at a flow rate of approximately 0.4 liters per minute for
24 hours for a resulting total air volume of approximately 0.6 ms. There will be either be
an arrow on the tube indicating the direction of the air flow or the technician should be
aware that air needs to flow into the section of the tube with the larger portion of sorbent.
Prior to collection, the end plugs of the carbon traps will be removed while wearing clean
gloves and placed into the bag in which the tube was received. At the completion of
sampling, these plugs will be placed back on the carbon traps while wearing clean gloves.
It is essential that these plugs be kept clean during the sampling process. Equipment and
supplies utilized with this sampling approach are as follows:
51
CITY_21MC100_003221704
NYC-WTC_000451245
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000451245Source: NYC Law Department, mirrored locally