U.S. Environmental Protection Agency Sampling Situation Report Saturday, September 29,2001 (11:30 AM)

Fixed Ambient Air Sampling Locations (Asbestos)

NYC / ER (Sept.26, 12:00 noon to 12:00 midnight) O All 16 samples (including 1 duplicate) were below the OSHA PCM standard and were also below the NYC reentry standard. However confirmatory TEM analysis showed that 4 of these 16 samples were above the AHERA standard (VOS/mm^). (Note: Sample volumes collected were lower than the recommended volumes but were adjusted to detennine if they exceeded established standards.)

O The four samples exceeding the AHERA standard had results of 163 s/mm2, 118 s/mm2, 296 s/mm2, and 74 s/mm2 and corresponded to locations D (East End of Albany Street at Greenwich Street), F (Northern media strip of Vesey and West Street), K (West Street and Albany Street in median strip) and Q (Barclay and West Street (center island), respectively. All these samples are within the immediately impacted area.

Fixed Ambient Air Sampling Locations (Asbestos)

NYC / ER (Sept.28, 12:00 midnight - 12:00 noon) O All 17 samples (including 1 duplicate) were below the OSHA PCM standard and were also below the NYC reentry standard. No samples exceeded the AHERA standard of 70S/mm2

New Jersey O Sept 26 - all 4 samples were below the established standards.

NYC Bulk/Dust Samples (Landfill)

Eight samples taken on Sept. 28 at the landfill were non-detect for asbestos.

Landfill Air Sampling locations (Asbestos)

11 air samples taken on Sept. 26 (8:00 AM - 6:00 PM) were below the established standards for all the methods analyzed. 11 air samples taken on Sept. 27 (7:30 AM - 6:30 PM) were below the established standards for all the methods analyzed. 11 air samples taken on Sept. 26-27 (6:30 PM on Sept .26 - 7:30 AM on Sept .27) were below the established standards for all the methods analyzed.

Direct Reading Instruments

Nothing of significance identified.

NYC Ambient Water Sampling

The seven water samples taken on Sept.25 showed no levels above the established Drinking Water MCL for asbestos of 7 MFL (million of fibers per liter).

CITY_21MC100_008691877

NYC-WTC_000454816

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000454816Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000234735

Report summarizing asbestos air sampling results from the New York City Emergency Response area for September 26 and 28, 2001.

Similar indexed content

NYC-WTC_000321055

Comprehensive air sampling results with TEM/PCM data and AHERA comparisons for Sep 29, 2001.

Similar indexed content

Compare copies and versions →