2002, ATC reported the results from the January 19, 2002 transmission electron
analysis (TEM) of air samples from P.S. 89. In a letter dated January 20, 2002, ATC
reported the results from the January 20, 2002 transmission electron analysis (TEM)
of air samples from P.S. 89. In a letter dated January 22, 2002, ATC reported the
results from the January 22, 2002 transmission electron analysis (TEM) of air
samples from P.S. 89. In a letter dated January 23, 2002, ATC reported the results
from the January 23, 2002 transmission electron analysis (TEM) of air samples from
P.S. 89. The analyses were performed in strict conformance with the methodology of
the AHERA Einal Rule for clearance of abatement sites. No asbestos was detected on
any occasion.\
16. In a letter dated December 31, 2001, ATC reported the results from the limited
asbestos bulk sampling tests conducted on December 19, 2001 at P.S. 89. Six bulk
samples were collected from ceiling and floor tiles from locations indicated by an
ENVIRON consultant. All six samples were analyzed utilizing Polarized Light
Microscopy (PLM). The three non-friable organically bound (NOB) floor tile bulk
samples were further analyzed utilizing Gravimetric Reduction Procedure followed
by PLM and Transmission Electron Microscopy (TEM). No asbestos was detected in
all bulk samples collected.
17. In a letter dated January 22, 2002, ATC reported the results from the January 21,
2002 Indoor Air Quality assessment measurements collected for P.S. 89M. In a letter
dated January 23, 2002, ATC reported the results from the January 22, 2002 Indoor
Air Quality assessment measurements collected for P.S. 89M. In a letter dated
January 25, 2002, ATC reported the results from the January 24, 2002 Indoor Air
Quality assessment measurements collected for P.S. 89M. ATC measured
temperature, relative humidity, CO2 and CO with a Q-Trak Model 8551. ATC also
measured concentrations of respirable particulates (PM2.5) with a Dust Trak Aerosol
Monitor Model 8520. ATC measured concentrations of TVOCs using a
photoionization detector (PID). There are no regulatory standards for indoor air
quality in non-industrial buildings. ATC used commonly accepted guidelines from
industry publications. In the January 22, 2002 report, concentrations of respirable
particulates, CO2,CO and TVOCs were within applicable standards and guidelines.
One indoor measurements of relative humidity were above the recommended range of
30 to 60 percent for occupant comfort. All other measurements were below the
recommended range. Seven temperature measurements were below the
recommended range of 68 to 75° F at 50 percent relative humidity during wintertime
conditions. In the January 23, 2002 report, concentrations of respirable particulates,
CO2,CO and TVOCs were within applicable standards and guidelines. Two indoor
measurements of relative humidity were above the recommended range of 30 to 60
percent for occupant comfort. All other measurements were below the recommended
range. Nine temperature measurements were below the recommended range of 68 to
75° F at 50 percent relative humidity during wintertime conditions. In the January
25, 2002 report, concentrations of respirable particulates, CO2,CO and TVOCs were
within applicable standards and guidelines. Indoor measurements of relative
humidity were above the recommended range of 30 to 60 percent for occupant
7