PROCEDURES OPERATION AND MAINTENANCE OF THE LANDFILL GAS PRODUCTION FACILITY AT FRESH KILLS LANDFILL
FKP-0019: LFG WELLFIELD - TEST EQUIPMENT CALIBRATION
Purpose
Wellfield optimization requires accurate LFG quality data. To ensure the data collected in the field is accurate, proper instrument calibration is required.
Equipment
• Certified Methane, Oxygen, and Carbon Dioxide calibration gases
Procedure
For instrument specific calibration instructions, refer to manufacturers recommended procedures. For all calibration procedures, calibration must employ a minimum of two calibration gases, a zero and a span (high end). The span gas should be within 20 to 50 percent of the regulatory limit (if one applies). Therefore, the span gas for oxygen calibration should be 4% oxygen. When calibrating for methane, ambient air can be used as a zero gas provided calibration is performed upwind from any methane sources. Some suggested calibration gases are as follows.
• For oxygen; zero can be set using a 15% CO2/15% CH4 calibration gas (balance nitrogen), and the span can be accomplished with a 4% O2 (balance nitrogen).
• For methane, zero can be set with ambient air, span can be set with either the 35% 002/50% CH4 calibration gas (balance nitrogen) or a 15% 002/15% CH4 calibration gas (balance nitrogen). The expected readings will dictate the appropriate calibration gas (i.e., if readings at the wellheads are anticipated to be approximately 55% GH4, the 50% GH4 span gas would be used).
• For carbon dioxide, the span can be set using 35% 002/50% CH4 calibration gas (balance nitrogen), and the zero can be accomplished with a 4% O2 (balance nitrogen).
• For methane surface emissions monitoring, the FID shall be calibrated with a 500 ppm methane calibration gas.
LFG Production Facility O&M 1 August 2003
CITY_21MC100_002335978
NYC-WTC_000454476
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000454384
Calibration procedures and gas standards for landfill gas monitoring at Fresh Kills.
1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421711
Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.
Similar document embedding; no shared entity or topic indexed. · similarity 0.808
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000428324
Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).
Similar document embedding; no shared entity or topic indexed. · similarity 0.808
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427221
Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.808
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449648
Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.807
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421972
QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.806
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421577
QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.806
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426556
Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.806
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426821
QA plan reference for deconstruction ambient air monitoring, Sept 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.806
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444248
QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.805
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000422676
QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.
Similar document embedding; no shared entity or topic indexed. · similarity 0.805
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423219
Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.
Similar document embedding; no shared entity or topic indexed. · similarity 0.805
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000428324
Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).
Similarity score 0.905 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438373
QA plan for ambient air monitoring at 130 Liberty Street deconstruction site, Sept 2005.
Similarity score 0.905 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441561
Quality Assurance Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, Aug 2005.
Similarity score 0.905 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000440540
QA Plan document for ambient air monitoring at the 130 Liberty Street deconstruction project, Sept 2005.
Similarity score 0.905 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421577
QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.
Similarity score 0.905 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000422676
QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.
Similarity score 0.905 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000454384
Calibration procedures and gas standards for landfill gas monitoring at Fresh Kills.
Similar indexed content
Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.
Similar indexed content
Draft QA project plan for Ambient Air Monitoring Program at 130 Liberty Street deconstruction (Aug 2005).
Similar indexed content
Draft QA Project Plan for ambient air monitoring at 130 Liberty Street deconstruction, TRC scope, Aug 2005.
Similar indexed content
Draft QA Plan for ambient air monitoring at 130 Liberty Street deconstruction project, Aug 2005.
Similar indexed content