Considerations
1. Asbestos fibers are an inhalation hazard and there has been no direct correlation
reported between settled dust and airborne levels. It can be inferred that higher
settled dust levels have the potential to lead to higher airborne levels, but
without a direct correlation, these levels would be based on supposition. The
use of aggressive (e.g. air circulating fans during sampling) TEM air samples
would be more appropriate in determining public risk.
2. The screening values are set with 1,000 17cm’ or the background. The
background level using microvac sampling is unknown. For practical purposes
the screening value is therefore being set at 1,000 f/cmc
The basis of the 1,000 17cm’ appears to be the analytical sensitivity for the
ASTM microvac sampling methodology. (ASTM D5755 §16.8- “An analytical
sensitivity of approximately 1000 asbestos structures/ cm’ [calculated for the
detection of a single asbestos structure] has been designed for this analysis”).
This is parallel to the discussions and criticisms of the current standards.
When determining the background, the presence of inplace ACM and the
history of ACM usage in the building must be obtained. Of particular concern,
the clearance for re-occupancy after an asbestos project has not included
microvac sampling. We do not know what level will be found at these sites
when compared to buildings constructed without ACM.
From time to time, there has been an interest in determining the background
levels in New York City. Some background air samples have been collected
during past emergency incidents. The Department had plans to perform the
necessary research with a background air monitoring study about ten years ago
but the contract and funding fell through.
From time to time, USEPA and DEP have received requests for the information
from research groups starting a project, therefore some data may be available
through outreach. In addition, the asbestos rules require background air
sampling prior to the start of an asbestos project. It is conceivable that a
research group may obtain these background air sample results.
3. The ASTM D5755 document indicates the following limitations;
5.1.1 This test method does not describe procedures or techniques required
to evaluate the safety or habitability of buildings with ACM or compliance
with federal, state or local regulations or statutes.
5.1.2. At present, a single relationship between asbestos containing dust and
potential human exposure does not exist.