Interim Air Sampling Report
Saturday, September 22, 2001
Investigators from the National Institute for Occupational Safety and Health (NIOSH) collected
air samples in areas immediately adjacent to the debris pile and on personnel actively involved in
rescue efforts in the vicinity of the debris pile to characterize potential exposures. Below are the
interim sampling results for Saturday, September 22, 2001.
Air Samples
Total Dust
• 4 area air samples were collected for total dust
o Area sample 8-hour time-weighted average concentrations were below 1.0 mg/m’
Respirable Dust
• 2 area air samples were collected for respirable dust
o Area sample 8-hour time-weighted average concentrations were below 0.05
mg/m’
Metals
• 4 area air samples were collected for metals
o Nothing of concern was found regarding metal analysis
Crystalline silica
• 2 area air samples were collected for crystalline silica
o No crystalline silica was detected on either of the air samples
Carbon Monoxide
• 7 real-time personal breathing zone samples were collected for carbon monoxide
o All 8-hour time-weighted average concentrations were below 20 ppm
o A single peak of 1239 ppm was observed on a torch cutter
Mercury
• 11 personal and 2 area air samples were collected for mercury
o No mercury was detected on any of the air samples