NYC-WTC_000243499
OCME memo about CCR contract to expand computerized case-tracking after WTC disaster.
2 shared non-person entities · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗Chain-of-custody/LIMS documentation for NYC Office of the Medical Examiner system.
NYC-WTC_000453885–000453999OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Office of the Chief Medical Examiner Version 2.1 Laboratory Information Management System RFP 27 October 2003
b. These alleles that are consecutively called are assigned the sample's DNA profile (results approval). c. Mixtures must be red-flagged for technical review (Need Calculations tool with algorithmic definitions).
9. Exemplar Processing a. Exemplars are cut in a separate room from evidence, but in a similar fashion. b. Swabs are placed in barcode tubes. c. Sample tube barcodes are scanned, and samples are assigned a well according to Beckman's tube to plate sample tracking software. d. Barcodes for extraction and amplification plates are printed, applied to the plates, and scanned e. Plate manifests are generated. The amplification plate includes amplification controls. Reagent barcode labels are scanned into the appropriate fields. f. Capillary electrophoresis proceeds as above. g- Suspect DNA profiles that initially match the DNA profile of the evidence are re-cut, re-extracted, re-amplified, and re-analyzed.
lO.DNA Profile Comparison (see Section 5.20.7) a. If an evidence sample does not generate a DNA profile, a batch report is generated. b. If an evidence sample generates z DNA profile, a separate batch report is generated. c. If the DNA profile of the evidence sample matches the exemplar's DNA profile, a more extensive report is generated and subject to technical review.
11. Digital Case File Contents a. The chain of custody window must have the updated location of the sample and the storage plates including the barcode of the refrigerator shelves, the respective date and time of storage, and the analyst's identifier. b. The case file must include the run date and time, the operator ID, the plate barcode and the plate map generated for each step of STR DNA typing on each instrument. c. The quantitation data for the standard curve controls, the extraction negative, and the sample data, and the electropherograms for the extraction negative, the amplification positive and negative controls, the allelic ladder, and the respective samples must be accessible in the appropriate window of the digital case file (see Section 5.20.11). d. The file must include a spreadsheet with the comparisons of both amplifications.
©1997-2003 Laboratory Automation Solutions, Inc. 70.
CITY_21MC100_0 12571854
NYC-WTC_000453954
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000243499
OCME memo about CCR contract to expand computerized case-tracking after WTC disaster.
2 shared non-person entities · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302111
Internal memo discussing potential headcount reductions in OCME records and related impact.
3 shared non-person entities · similarity 0.893
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454156
Memorandum detailing WTC identifications and FEMA-extension notes.
4 shared non-person entities · similarity 0.905
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243528
OCME update: FEMA extension through 2005; CCR funding not yet approved.
2 shared non-person entities · similarity 0.900
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105016
Document summarizing results of bulk sample and air monitoring tests at 110 Greenwich Street.
1 shared non-person entities · similarity 0.898
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243526
OCME note on FEMA extension through 2005 and CCR funding status.
2 shared non-person entities · similarity 0.897
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
3 shared non-person entities · similarity 0.893
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117757
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
2 shared non-person entities · similarity 0.893
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121462
Record documenting the transfer and custody of air samples from Building #500 at 385 South End Avenue collected on October 22, 2001.
4 shared non-person entities · similarity 0.891
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437748
EPA-compiled plan for Environmental Community Air Monitoring Program, 2005.
3 shared non-person entities · similarity 0.891
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280647
Doc header for health monitoring and sampling RFP, 10/01/01, contract file.
2 shared non-person entities · similarity 0.890
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000188121
Request for Proposal document from October 1, 2001, regarding health monitoring and sampling at the World Trade Center emergency site.
2 shared non-person entities · similarity 0.890
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000245464
Permit application unrelated excerpt; contains mayoral report and NYC identifiers; likely overarching documents for school-related permit.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000412760
The Talk of the Town column discusses post-9/11 civilizational divisions and general reflections.
Similarity score 0.932 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000345107
Log/CoC for PCM sampling; TEM/CoC at site.
Similarity score 0.928 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000343560
Air monitoring log/chain-of-custody form for PCM/TEM analysis at EPA Level II.
Similarity score 0.925 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000346331
Air monitor log and chain-of-custody form; PCM analysis method and locations.
Similarity score 0.925 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000343911
Information and guidelines for PCM and TEM analysis and CoC submission.
Similarity score 0.925 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000243499
OCME memo about CCR contract to expand computerized case-tracking after WTC disaster.
Similar indexed content
NYC-WTC_000454156
Memorandum detailing WTC identifications and FEMA-extension notes.
Similar indexed content
NYC-WTC_000243528
OCME update: FEMA extension through 2005; CCR funding not yet approved.
Similar indexed content
NYC-WTC_000105016
Document summarizing results of bulk sample and air monitoring tests at 110 Greenwich Street.
Similar indexed content
NYC-WTC_000243526
OCME note on FEMA extension through 2005 and CCR funding status.
Similar indexed content