Office of the Chief Medical Examiner Version 2.1 Laboratory Information Management System RFP 27 October 2003

code scans. d. The extraction storage plate is stored in the refrigerator, and the bar code on the plate as well as the refrigerator shelf is scanned.

4. Quantitation and First Amplification (see Section 5.20.5) a. The control and sample quantitation values must be accessible in the appropriate window in the digital case file. b. Quantitation values from Synergy HT plate reader re communicated to the Biomek FX through the Silas module. c. The barcode on the quantitation plate is scanned, and according to the Biomek FX normalization wizard, eligible samples are assigned wells in the amplification storage plate and the first amplification plate. d. A new plate map is generated and barcodes are assigned, printed and applied to the amplification storage plate and the first amplification plate. Amplification controls are added. Fields for reagent lot numbers accept barcode scans. e. The amplification storage plate is stored in the refrigerator, and the barcode on the plate as well as the refrigerator shelf is scanned.

5. Capillary Electrophoresis a. Amplification plate is scanned. A 3100 run sheet is generated with an allelic ladder control. The amplification plate reagent barcode and other reagent barcodes are scanned. b. Upon Supervisory review, a run is passed and the extraction, amplification, and CE controls as well as the sample data are automatically linked to the respective digital case files.

6. Second Amplification a. Based on the CE results from the first amplification, samples are selected for re-amplification. b. The amplification storage plates are scanned. c. Using the hit picking wizard on the Biomek2000 and/or the Biomek FX samples are selected, assigned new sample wells, and aliquotted for second amplifications d. A plate map for the second amplification is generated with new amplification controls. e. A barcode is assigned, printed and applied to the plate.

7. Second Capillary Electrophoresis Run a. Occurs with same requirements as above.

8. Allelic Calling (see Section 50.20.11). a. DNA profiles from the first and second amplifications are put into a spreadsheet (Need to view via LIMS).

©1997-2003 Laboratory Automation Solutions, Inc. 69.

CITY_21MC100_0 12571853

NYC-WTC_000453953

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453953Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →