Office of the Chief Medical Examiner Version 2.1 Laboratory Information Management System RFP 27 October 2003

The delivered LIMS shall match individual specimens with their respective QC batch and allow access to the associated QC results. The delivered LIMS shall provide a place for comments, both on the specimen preparation worksheets and analysis reports, to describe any unusual circumstances or pertinent information. These comments shall be retrievable and associative to the data for which it was originally intended.

Plate manifests that are created for the extraction storage plate, the Quantitation plate, the first amplification plate and amplification storage plates, the first 3100 run, the second amplification plate, and the second 3100 run, shall be accessible, if not created, by the LIMS. As each subsequent plate is created from its predecessor, the sequence and number of samples may change due to negative results. The LIMS shall track and re-assign the samples, in proper sequence, as a subset of each predecessor originating from the first plate in the series of tests. The LIMS shall perform this function automatically based on any negative results recorded for samples in each step of the sequence.

5.20.5.4 Specimen Ho/d Times and Turnaround Times

Many analyses performed by the laboratory specify a maximum hold time for the analysis to be conducted. The delivered LIMS shall assign holding times by predefined limits assigned to test codes, as well as accommodate rush work or non-standard turnaround requests. The on-screen display shall include a user- controlled filter to define the scope of the listed specimens. The delivered LIMS shall generate lists of all pending work according to the remaining holding time or turnaround requested, and allow the analyst and laboratory management to differentiate between the two. The delivered LIMS shall also differentiate between allowable holding times for different types of specimens. The delivered LIMS shall automatically alert specific analysts and/or group leaders, electronically, that prompt action is required according to predefined criteria.

The delivered LIMS shall have a mechanism for alerting analysts and management when specimens are about to reach the end of allowable holding times. There shall be an easy way to determine if all requested analyses have been completed so that the specimen can be disposed.

5.20.6 eStatus Tracking The delivered LIMS shall assign status values when specimens are received, logged and processed by the lab, such as the following:

> Received > Stored > Prepared

©1997-2003 Laboratory Automation Solutions, Inc. 51.

CITY_21MC100_0 12571835

NYC-WTC_000453935

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453935Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →