QA Plan for Air Monitoring Program, Sept 2005

Machine-extracted title · confidence 55%

Quality Assurance Project Plan for environmental air monitoring and waste management at Greenwich and Thames sites; Sept 30, 2005.

NYC-WTC_000423885–000423994
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - September 29, 2005

14.4.2 Fixed Laboratory Data Package Deliverables

14.4.2.1 Hardcopy Deliverables Data deliverables for the fixed laboratories will consist of sample and QC results. At a minimum, the data packages from the analytical chemistry laboratories will include the following:

1. Case narrative

• summary of analytical methods used • correlation of field sample identifications and laboratory sample identifications • data qualifier definitions • deviations from established QA/QC procedures with corrective action

2. Sample results

• project name • field sample identification • batch number • col lection exlmction analysis dates • sample results calculated based on the air volume sampled • quantitation limits • dilution factors • TEQs (for dioxin/furan results) • BAP-equivalent concentrations (for PAH results)

3. Sample documentation

• original chain-of-custody • shipping documents • cooler receipt forms

4. Quality Assurance/Quality Control

• method blanks • spike recoveries (surrogates, MS/MSDs, LCSs, internal standards, field spikes) • measures of precision (laboratory duplicates, LCS/LCSDs) • summary of tune and calibration results • control limits for accuracy and precision

Depending on the analysis, analytical results will be reported within 24 hours or three (3) to five (5) business days of receipt of samples by the laboratory. Nondetect results must be reported down to the quantitation limit and qualified with a U. All

89

CITY_DEP_WORBY_CANNATA_SUBP_000071023

NYC-WTC_000423973

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423973Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451195

QA plan for environmental air monitoring and waste management at NYC sites.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →