NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
14.4.2 Fixed Laboratory Data Package Deliverables
14.4.2.1 Hardcopy Deliverables Data deliverables for the fixed laboratories will consist
of sample and QC results. At a minimum, the data packages from the analytical chemistry
laboratories will include the following:
1. Case narrative
• summary of analytical methods used
• correlation of field sample identifications and laboratory sample
identifications
• data qualifier definitions
• deviations from established QA/QC procedures with corrective action
2. Sample results
• project name
• field sample identification
• batch number
• col lection exlmction analysis dates
• sample results calculated based on the air volume sampled
• quantitation limits
• dilution factors
• TEQs (for dioxin/furan results)
• BAP-equivalent concentrations (for PAH results)
3. Sample documentation
• original chain-of-custody
• shipping documents
• cooler receipt forms
4. Quality Assurance/Quality Control
• method blanks
• spike recoveries (surrogates, MS/MSDs, LCSs, internal standards, field
spikes)
• measures of precision (laboratory duplicates, LCS/LCSDs)
• summary of tune and calibration results
• control limits for accuracy and precision
Depending on the analysis, analytical results will be reported within 24 hours or three
(3) to five (5) business days of receipt of samples by the laboratory. Nondetect results
must be reported down to the quantitation limit and qualified with a U. All
89
CITY_DEP_WORBY_CANNATA_SUBP_000071023
NYC-WTC_000423973
OCR can misread numbers and units. Confirm readings against the page image before using them.