NYC 9/11 Public Portal Document
Summary of Asbestos Sampling Results
70 Battery Place, New York, N.Y. 10280
Date sampled: November 19, 2001
Four locations were sampled at your building: inside two private residences, an indoor common
area (e.g., a lobby or hallway), and a nearby outdoor area (see tables below for sampling results).
One air sample was collected in each of the four locations , two dust samples were collected
outside and one settled dust sample was collected at each of the indoor locations.
Air samples were collected using vacuum pumps to draw air past a filter that was suspended at
the height of a person’s breathing level. Outdoor dust and debris samples were collected by
placing visible material in a container. Indoor dust and debris samples were collected on a filter
by vacuuming surfaces. The collected material was weighed, viewed under a microscope, and/or
chemically processed to determine the types and quantities of substances present. The materials
were analyzed for fibers such as asbestos, fiberglass, synthetics (e.g. man-made materials such as
nylon and polyester), cellulose (e.g. cotton, paper), silica, and for other minerals and small
particles.
ASBESTOS AIR TEST RESULTS
Results of all of the air samples taken from your building were below the standard set for indoor
air quality - 0.01 fibers per cubic centimeter (f/cc) (see attached results). The highest level of
fibers in the air at your building was 0.002 f/cc. This air level is comparable to the air results
from buildings located above 50 Street, which are not expected to have been impacted by WTC
materials. In the homes above 59" Street, levels of fibers found in the air ranged from less than
0.001 f/cc to 0.003 f/cc. This indicates that the air levels for fibers from your building are
similar to those seen in areas not impacted by the dust from the WTC collapse.
The air samples tested from directly outside and in the lobby of your building were taken during
normal daily activity. The two air samples from the unoccupied apartments were taken after the
dust in the apartment was aggressively “stirred up” to ensure that an accurate sample of particles
would be present. All air samples were examined in a laboratory for fibers using the Phased
Contrast Microscopy (PCM) method.
Airborne fibers as determined by PCM: An air sample is collected by pulling air through a
filter. The filter catches fibers and is sent to a laboratory to determine what types of fibers were
in the ah’. Phase contrast microscopy identifies fibers based on size and shape, but not the
specific type of fiber. Therefore, the fibers seen by PCM include asbestos fibers as well as other
fibers, such as textiles, fiberglass, cellulose, which might be present in your home. The PCM
analysis assumes that all fibers present were asbestos. Therefore, less hazardous fibers that may
have been present, such as textiles or fiberglass, are counted along with the asbestos fibers, and
the total fiber count is then compared to the asbestos standard. If the levels had been elevated
using the PCM methodology, additional analysis would have been performed to determine
whether any of the fibers were asbestos.