I New York City School Construction Authority SCA Project Manager: Marsha Soroka 1 Contract#: C000008706 Project #: M894-14630, LLW# 028913

PROJECT REPORT

I Section 1.0 Project Summary

Taylor Environmental Group, Inc. (“TEG”) was retained by Mrs. Marsha Soroka of the New I York City School Construction Authority (“SCA”) on October 11, 2001, to perform environmental consulting services at High School for Leadership & Public Service, located at 90 Trinity Place, New York, NY. The consultant services were to be performed in conjunction with clean up work as outlined in SCA Monitor Proceed Order #M894-14630, LLW#028913. A copy of this request letter is appendixed to this Report.

The requested services included project monitoring, air monitoring, analysis of air samples collected during the project, collection and analysis of bulk material samples and project

I management throughout the project. The proposed work consisted of the following:

Location Type of Material Method Basement & Floors 1-14 General Cleaning Wet Clean Up/ HEPA Vacuum

Following authorization to proceed from SCA representative Marsha Soroka, the clean-up project commenced on November 19, 2001. Trio Asbestos Removal Corporation was the on-site contractor for the project. Physical completion of the work was achieved on February 1, 2002.

I Analysis of phase contrast microscopy samples and transmission electron microscopy post­ abatement samples collected was performed by EMSL Analytical, Inc., an ELAP and NVLAP certified environmental laboratory. I Section 1.1 Sampling Methods

I Air samples were collected using high-volume sampling pumps. The sample unit for phase contrast microscopy (PCM) analysis consisted of a cellulose ester membrane filter (pore size 0.8 microns) and a support pad contained in a three-piece styrene plastic cassette. The sample unit I for transmission electron microscopy (TEM) consisted of a cellulose ester membrane filter (pore size 0.45/5 micron backing filter) and a support contained in a three-piece styrene cassette. All pumps were calibrated at the start and at the conclusion of the sampling period.

Section 1.2 Analytical Methods

The method used for phase contrast microscopy (PCM) sample analysis is that recommended by the National Institute for Occupational Safety and Health (NIOSH) Method 7400/Counting Rules A. An outline of this method is appendixed to this Report. According to this procedure, the I minimum total fiber count in 100 fields considered adequate for reliable quantification is 5.5 fibers. This value corresponds to 3,433 fibers per filter for 25 mm filters. When the fiber count falls below 5.5 fibers in 100 fields, the concentration is calculated using these figures and a "less I than" (<) sign is used to indicate this is a minimum detectable concentration. Analytical detection limit X 5.5

I MFA 100

I TAYLOR ENVIRONMENTAL GROUP, INC., 130A JERICHO TURNPIKE, FLORAL PARK, NY 11001

CONFIDENTIAL, CITY_2IMCl00_007895427

SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000453470

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000453470Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000432851

Project report for Stuyvesant High School LLW submission, 2003.

Similar indexed content

NYC-WTC_000432872

Lab report for LLW sampling at HSEF, Trinity Place, 2003.

Similar indexed content

Compare copies and versions →