NYC Emergency Response
Asbestos Air Sampling Results NYC ER/NJ DEP
Date SampSing Sample PCM by NiOSH 7400 TEM ( AHERA)
Sampled Sample No. Location Volume Matrix f/mm" f/cc 0.5p-5p I 5p S/mnf S~f/cc*
S(#)
10/10/01 01991 Liberty Park 480 Air <7.0 <0.006 0 0 <6.15 <0.0049
1 0/10/01 01992 ITGO Termin 480 Air <7.0 <0.006 0 0 <6.15 <0.0049
10/10/01 01993 ■MC Termina 480 Air 7.01 <0.006 0 0 <6.15 <0.0049
1 0/10/01 01994 Shell Termina 480 Air <7.0 <0.006 0 0 <6.15 <0.0049
coc#O4189
PCM: Phase Contrast Microscopy by NIOSH 7400
TEM: Transmission Electron Microscopy (TEM) EP.A 40CFR Part 763 (AHERA). Sample volume is below recommended limit of the method.
"Structure (S) roughly equivalent to Fiber (f)
Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm®, Volume 1200 L, for 25 mm filter (TEM)
Period in which samples were collected and retrived
Sampling Location Sampling Times
Liberty Park 1310(1 0/10/01) - 2110 (101 08/01)
CITGO Terminal 1355 (1 0/10/01) - 2155 (10/10/01) ERT: 10/12/01 09:50 AM
FMC Terminal 1425 (10108/01) -2225(10/10/01)
Shell Terminal 1440 (1010/01)- 2240 (1 0/1 0/01)