NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 129 pages

Plan for Environmental Community Air Monitoring

Machine-extracted title · confidence 50%

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

NYC-WTC_000451808–000451936
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

PAHs/GC/MS Check connections. Replace disposables. Perform injection port maintenance. Clip column. Perform leak checks. Clean detector. Pesticides, Herbicide, &PCBs/GC/ECD Check connections. Replace disposables. Perform injection port maintenance. Clip Column,. Perform leak checks. Clean detector.

Dioxins & Furans/HRGC/HRMS Check connections. Check connections. Replace disposables. Perform injection port maintenance. Clip Column,. Perform leak checks. Clean detector.____________________________________ Asbestos/TEM Align and check TEM scope. Calibrate for Al/Cu EDX response daily._____________________________________ Silica/XRD Check daily or Si-primary peak, displacement, and detector resolution.________________________________________ Mercury/CVAFS Check fitting, rinse and refill DDIW bottle, prepare new pretraps, blank each analytical trap. Soak bubblers in 1% KOH solution. Change traps, replace lamps, clean/charge quartz cell. Inspect tubing, replace fittings, prep new stock standards. Mercury/CVAA Check fitting, rinse and refill DDIW bottle, prepare new pretraps, blank each analytical trap. Soak bubblers in 1 % KOH solution. Change traps, replace lamps, clean/charge quartz cell. Inspect tubing, replace fittings, prep new stock standards. Corrosivity/pH meter Condition probe when fluctuations occur._______________ PM 10 Annual calibration of balance by outside certification.( ) PM 25 Annual calibration of balance by outside certification.( )

'. Annual calibration records will be maintained by the Quality Assurance Officer.

90

CONFIDENTIAL, CITY_21MC100_007850000 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000451897

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451897Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000440780

Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.

Similar indexed content

Compare copies and versions →