Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - January 27, 2006

PAHs/GC/MS Check connections. Replace disposables. Perform injection port maintenance. Clip column. Perform leak checks. Clean detector. Pesticides, Herbicide, &PCBs/GC/ECD Check connections. Replace disposables. Perform injection port maintenance. Clip Column,. Perform leak checks. Clean detector.

Dioxins & Furans/HRGC/HRMS Check connections. Check connections. Replace disposables. Perform injection port maintenance. Clip Column,. Perform leak checks. Clean detector.____________________________________ Asbestos/TEM Align and check TEM scope. Calibrate for Al/Cu EDX response daily.____________________________________ Silica/XRD Check daily or Si-primary peak, displacement, and detecto resolution.________________________________________ Mercury/CVAFS Check fitting, rinse and refill DDIW bottle, prepare new pretraps, blank each analytical trap. Soak bubblers in 1% KOH solution. Change traps, replace lamps, clean/charge quartz cell. Inspect tubing, replace fittings, prep new stock standards. Mercury/CVAA Check fitting, rinse and refill DDIW bottle, prepare new pretraps, blank each analytical trap. Soak bubblers in 1% KOH solution. Change traps, replace lamps, clean/charge quartz cell. Inspect tubing, replace fittings, prep new stock standards. Corrosivity/pH meter Condition probe when fluctuations occur.______________ PM 10 Annual calibration of balance by outside certification. (^)

Annual calibration records will be maintained by the Quality Assurance Officer.

93

CITY_DEP_WORBY_CANNATA_SUBP_000093281

NYC-WTC_000427049

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000427049Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000425068

Title and approval sheet for Environmental Community Air Monitoring Program and plan at Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427415

CoC document detailing plan for Environmental Community Air Monitoring at Greenwich Street sites.

Similar indexed content

NYC-WTC_000424476

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000426688

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

Compare copies and versions →