Ambient air monitoring program plan, Liberty Street project, Sep 2005

Machine-extracted title · confidence 42%

Quality assurance plan for ambient air monitoring at the Liberty Street deconstruction site, Sep 2005.

NYC-WTC_000451508–000451641
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ambient Air Monitoring Program Section No. 11 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 1, 2005 Lower Manhattan Development Corporation Page 79 of 124

11.2.2.2 Instrument Blanks

Instrument blanks are used to evaluate contamination resulting from the analytical reagents and the instrumentation. In addition, instrument blanks are sometimes used to assess potential carryover after the analysis of a highly contaminated sample. Instrument blanks are only required for select analytical parameters.

11.2.2.3 Surrogate Spikes

Surrogate spikes are used to evaluate extraction efficiency or analytical bias on a sample by sample basis for organic parameters. Surrogate spikes are added to all samples for organic parameters. Surrogate spikes are another measure of sample-specific QC.

11.2.2.4 Laboratory Control Samples

Laboratory control samples (LCSs) and LCS Duplicates are used to evaluate almost all parameters for the ability of the laboratory to accurately and precisely identify and quantitate target compounds in a reference matrix when spiked at the mid range of the calibration curve at a known concentration using a secondary source standard. LCSs and/or LCS Duplicates are typically performed as part of each analytical batch for each methodology with the exception of asbestos, PMw and PM2.5.

11.2.2.5 Laboratory Duplicate

Laboratory duplicates are used to evaluate laboratory preparation and analysis precision. These analyses are typically performed for inorganic parameters only. Laboratory duplicates are typically performed at a frequency of one per twenty samples.

11.2.2.6 Internal Standards

Internal standards are used to assess the analytical accuracy, precision, and stability. Internal standards are typically only used for organic analyses and ICP/MS analyses. Internal standards are spiked into all samples and are considered a sample-specific QC measure.

11.2.2.7 Standard Reference Materials

Standard reference materials (SRMs) are used to evaluate laboratory preparation and analysis bias for specific compounds in a reference matrix. SRMs will be used for the asbestos analysis.

L2005-346 Rev. 1

CITY_21MC100_0 02652002

NYC-WTC_000451587

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000451587Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000440540

QA Plan document for ambient air monitoring at the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000421577

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

Compare copies and versions →