NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
Preservation should be performed at time of sample collection. Sample bottles with or without preservative
may be obtained by contacting the laboratory. Indication of preservative would be helpful either on the
label or a sample chain of custody (also available from the laboratory). The holding times listed in the table
are the maximum allowable time a sample can be held before analysis and still be in compliance with the
EPA regulations. Sample collection date and time are needed to ensure that holding times are met properly.
10.3 Field Quality Control
This section of the QAPP identifies the QC procedures, checks, samples, and their
respective acceptance limits, that will be used to monitor the quality of various aspects of
the sampling event. Their required analysis frequency, acceptance limits and corrective
actions are also documented in this section of the QAPP.
10.3.1 Field Blanks/Trip Blanks
Field/trip blanks consist of clean sample media. Field/trip blanks accompany samples to
the site and return to the laboratory in the same cooler or shipping container. Field/trip
blanks will be used to ensure that there is no contamination as a result of the
shipment/transportation/on-site storage activities. Field/trip blanks will be collected for
all parameters associated with air samples. Field/trip blanks for asbestos and silica will
only be analyzed if the asbestos or silica are detected in the associated samples.
10.3.2 Cooler Temperature Blanks
Cooler temperature blanks consist of a sample container filled with non-preserved water
(potable or distilled) and arc included in all coolers which contain samples which require
temperature preservation (PAHs, PCBs, PCDDs/PCDFs). The laboratory uses these
temperature blanks to ensure that proper preservation of the samples has been maintained
during sample shipment. The temperature of these blanks must be 4 “C ±2° to
demonstrate that proper preservation has been maintained. The laboratory records the
results of the temperature blanks on the chain-ofeustody or sample login form
immediately upon receipt of the samples at the laboratory, prior to inventory and
refrigeration.
10.3.3 Field Duplicates
Field duplicates will be collocated samples. Collocated samples are two samples
collected next to each other in the same vertical position. Collocated samples require two
separate sample collections at the same location. Field duplicates will be used to assess
the sampling and analytical reproducibility. With the exception of total mercury, field
duplicates will be submitted at a frequency of once per week per analytical parameter.
For total mercury, field duplicates and field spikes will be alternated on a weekly basis.
57
CITY_21MC100_0 03221710
NYC-WTC_000451251
OCR can misread numbers and units. Confirm readings against the page image before using them.