NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
Dibenzofurans (PCDFs)
Ambient air samples will be collected using a General Metals Works (GMW) PS-1
(or performance equivalent) high volume air sampling system equipped for the collection
of semivolatile PCDD/PCDF particulate matter on a 102-mm diameter microquartz fiber
filter, as well as a glass cylinder containing a polyurethane sorbent (i.e., PUF plug) for
the collection of gas phase PCDDs/PCDFs. At each site, one GMW PS-1 sampler will be
used to collect PCDD/PCDF samples according to Method TO-9A. Samples will be
collected at a flow rate of 200 to 300 liters per minute (1pm) over a sampling period of
approximately 24 hours for a resulting total air volume of approximately 288-432 cubic
meters (288-432 ma). The PUF (Polyurethane Foam) sampler is a complete air sampling
system designed to simultaneously collect suspended airborne particulates as well as trap
airborne organic vapors. The PUF sampler is equipped with a bypass blower motor
arranged with an independent cooling fan. This feature permits the motor to operate at
low sampling flow rates for extended periods without motor failure from overheating. A
dual chambered aluminum sampling module contains both filtering systems. The
upper chamber supports the airborne particulate filter media in a circular filter holder.
The lower chamber encapsulates a glass cartridge, which contains the PUF for vapor
entrapment. The voltage variator adjustment screw alters the blower motor speed to
achieve the desired flow rate. Air flow rate is measured through the flow venturi utilizing
a 0-100” Magnehelic Gage. For each sample, the sampling start and end times and flow
rates are recorded on Field Sampling Data Sheets or an equivalent field logbook and used
to calculate the amount of ambient air sampled. At the conclusion of each sampling
period, the sample is recovered from the sampling train by placing the filter inside the
glass cartridge. The glass cartridge is then wrapped with aluminum foil and it is placed
back into its original shipping container, labeled, and transported to the analytical
laboratory for processing. Equipment and supplies utilized with this sampling approach
are as follows:
• High-Volume Sampler - General Metals Works (GMW) PS-1 (or equivalent),
capable of pulling ambient air through the filter/adsorbent cartridge sampling train
at a flow rate of 200- 300 Ipm to obtain a total sample volume of 288-432 m3 over
a 24-hour period. • High-Volume Sampler Calibrator - Capable of providing
multipoint resistance for the highvolume sampler.
• Quartz Fiber Filters - 102 millimeter (102-mm) bindless quartz micro fiber filter,
Whatman International Ltd, QMA-4 (or equivalent), provided by the laboratory,
pre-cleaned and weighed.
• Polyurethane Foam (PUF) Plugs - 3-inch thick sheet stock polyurethane type
(density 0.022 g/cm3). Plugs should be slightly larger in diameter than the internal
diameter of the cartridge.
• Teflon® End Caps - For sample cartridge. Must fit tightly to provide an adequate
seal to prevent pre- or post- sampling exposure to other potential sources of the
target analytes.
• Glass Sample Cartridge - For sample collection. The analytical laboratory will
insert the PUF plug into the glass sample cartridge during pre-sampling
preparation. • Sample Cartridge Aluminum Shipping Containers - The analytical
48