NYC-WTC_000423693
QAPP amendment increasing mercury spike level from 50 to 150 ng/trap for improved accuracy.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗QAPP amendment updating mercury spike level from 50 ng to 150 ng.
NYC-WTC_000451189–000451191OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
QAPP AMENDMENT FORM
The flow rate for asbestos sampling will be reduced from 6 Liters/minute to approximately 3.7 Liters/minute on Monday through Friday. In addition, the sampling flow rate will stay at 6 Liters/minute on Saturdays and Sundays when eight-hour samples are collected. The sampling times will remain the same as indicated in Amendment # 4. Note going forward the flow rate of samples will be adjusted from 1 to 10 liters per minute, based on the anticipated Contractor work shift duration for that day to attain a sample volume of approximately 2.88 m’. Sample volumes on Monday through Friday will therefore decrease from approximately 4.68 m"" to approximately 2.88 m^. Reason for Amendment: As agreed upon in a teleconference with EPA on October 5, 2005, the flow rate for asbestos sampling was reduced on Monday through Friday to avoid the collection of excessive volume and possible overloading of the filters. The reduced flow rate allows for the achievement of the 2.88 m^ volume which was approved in the September 7, 2005 version of the QAPP. This volume is the minimum volume needed by the laboratory to ensure the required analytical sensitivity is achieved. Sections of QAPP Affected: Section 10.2.3, Asbestos: The flow rate for asbestos sampling will be reduced from 6 Liters/minute to approximately 3.7 Liters/minute on Monday through Friday for a resulting total air volume of approximately 2.88 m^. Table 12-1: The flow rate for asbestos sampling will be reduced from 6 Liters/minute to approximately 3.7 Liters/minute on Monday through Friday for a resulting total air volume of approximately 2.89 m^. Date Implemented: The change in asbestos sampling flow rate was implemented on October 6, 2005.
Pages of3
CITY_21MC100_0 03220769
NYC-WTC_000451191
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000423693
QAPP amendment increasing mercury spike level from 50 to 150 ng/trap for improved accuracy.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446799
QAPP amendment documenting mercury spike level increase from 50 to 150 ng.
7 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441952
QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.
7 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427863
QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.
7 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425322
QAPP amendment modifying mercury spike level to 150 ng for field samples, Oct 2005.
7 shared non-person entities · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000425341
QAPP amendment detailing calibration and flow-rate procedures for metals samplers; dated 4/5/06.
7 shared non-person entities · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451394
QAPP amendment detailing flow rate and calibration changes for high-volume samplers, submitted 2006.
7 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
4 shared non-person entities · similarity 0.909
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
4 shared non-person entities · similarity 0.905
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162838
Correspondence regarding Schedule A forms and a draft scope of work for cleaning and air monitoring contracts at the site.
4 shared non-person entities · similarity 0.905
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
4 shared non-person entities · similarity 0.905
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
4 shared non-person entities · similarity 0.905
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000423693
QAPP amendment increasing mercury spike level from 50 to 150 ng/trap for improved accuracy.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423693
QAPP amendment increasing mercury spike level from 50 to 150 ng/trap for improved accuracy.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445893
Section 2 comments on ambient air monitoring criteria for abatement projects.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427338
Section 2 comments re criteria for ambient air monitoring plan, June-Aug 2005.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441952
QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445115
Comments on ambient air monitoring plan related to the 130 Liberty Street project.
Similarity score 0.948 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000423693
QAPP amendment increasing mercury spike level from 50 to 150 ng/trap for improved accuracy.
Similar indexed content
QAPP amendment documenting mercury spike level increase from 50 to 150 ng.
Similar indexed content
QAPP amendment changing mercury spike level from 50 to 150 ng in 2005.
Similar indexed content
QAPP amendment to raise mercury spike from 50 ng to 150 ng for improved recoveries.
Similar indexed content
NYC-WTC_000425322
QAPP amendment modifying mercury spike level to 150 ng for field samples, Oct 2005.
Similar indexed content