NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 132 pages

Quality Assurance Plan, Ambient Air Monitoring

Machine-extracted title · confidence 66%

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

NYC-WTC_000449908–000450039
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z ■<

o Ambient Air Monitoring Program Section No. 8 o co g Quality Assurance Project Plan Revision No.: 0 o 130 Liberty Street - NY, NY Date: September 7, 2005 “0 I o Lower Manhattan Development Corporation Page 47 of 124 c o CT o o' CD "0 CD o tn 03 cn Table 8-3. Measurement Performance Criteria Table - PAHs by GC/MS-SIM O o QC Sample or Activity Frequency Measurement Performance Criteria Corrective Action DQI o c Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, and/or Precision-Overall 3 o samples are > 5x QL qualify data. 3 *No situatiorr where one result is detected at > 5x QL and other result is not detected Internal Standards Every sample. Percent recoveries 25-150% Reanalyze and/or qualify data. Accuracy/Bias (extraction spike) blank, QC Method Blanks 1/batch No target compounds > QL Reclean, reanalyze and/or qualify Accuracy/Bias- data. Contamination Field/Trip Blanks l/day'^’ No target compounds > QL Reclean, reanalyze, and/or qualify Accuracy/Bias - data. Contamination Laboratory Control Sample 1/batch Percent recoveries 60-140% Determine cause of problem, Accuracy/Bias reanalyze, and/or qualify data. Laboratory Control Sample 1/batch Percent recoveries 60-140%; RPDs < 50 Determine cause of problem, Accuracy/Bias and Dupheate reanalyze, and/or qualify data. Precision Recovery Standards Every sample, -50% to +100% of area counts in Reanalyze and/or qualify data. Accuracy/Bias (pre-analysis spike) blank, QC continuing calibration standard; + 20 seconds of retention times in continuing calibration standard Field Spike Every Sample Percent recoveries 60-120% Reanalyze and/or qualify data. Accuracy-Overall (prior to sampling)-13C- fluorene at 1000 ng Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness PUF/XAD Media Cleaning 1/batch cleaned No target compounds > QL Reclean and retest media. Accuracy/Bias- Verificatiorr Check Contaruinatiorr PFTBA Tune Every day, prior Masses within 0.45 amrr of target mass for Rehine instrument, reanalyze PFK. Accuracy/Bias to saiuple ruasses 69, 219, and 264 o analysis H K Field duplicates may not be consistently collected at a frequency of 1/week during Phases I and II as the location selected for analy sis will be dictated by PMio measurements. I (2) Will be collected at a frequency of 1/day; during Phase I and II only 1 field/trip blank per week will be analyzed. to s O Reanalyze: refers to reanalysis of same extract.

o o I o o co to co o co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000449955Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000444248

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

Compare copies and versions →